NICE7000 User Manual 6 Function Code Table
- 121 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
FA-15
Program control
selection
Bit0: Super short floor function
Bit1: Up slow-down not reset for
super short floor
Bit2: Down slow-down not reset
for super short floor
Bit3: Cancelling monitoring at
leveling and slow-down
Bit4: Slow-down stuck detection
Bit5: Canceling 45s time limit at
shaft auto-tuning
Bit6: Leveling adjustment
0
-
★
Group Fb: Door function parameters
Fb-00
Number of door
machine(s)
1–2
1
-
★
Fb-01
Door function
selection
0–65535
0
-
●
Fb-02
Service floors 1 of
door machine 1
0–65535
65535
-
☆
Fb-03
Service floors 2 of
door machine 1
0–65535
65535
-
☆
Fb-04
Service floors 3 of
door machine 1
0–65535
65535
-
☆
Fb-05
Service floors 4 of
door machine 1
0–65535
65535
-
☆
Fb-06
Service floors 1 of
door machine 2
0–65535
65535
-
☆
Fb-07
Service floors 2 of
door machine 2
0–65535
65535
-
☆
Fb-08
Service floors 3 of
door machine 2
0–65535
65535
-
☆
Fb-09
Service floors 4 of
door machine 2
0–65535
65535
-
☆
Fb-10
Door open
protection time
5–99
10
s
☆
Fb-11
Forced door close
time
5–99
15
s
☆
Fb-12
Door close
protection time
5–99
15
s
☆
Fb-13
Door re-open times 0–20
0
-
☆
Summary of Contents for NICE7000
Page 1: ......
Page 15: ......
Page 16: ...1 Safety Information and Precautions ...
Page 23: ...1 Safety Information and Precautions NICE7000 User Manual 22 ...
Page 24: ...2 Product Information ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 71: ...4 Use of the Commissioning Tools ...
Page 79: ...5 System Commissioning and Functions ...
Page 102: ...5 System Commissioning and Functions NICE7000 User Manual 100 ...
Page 103: ...6 Function Code Table ...
Page 134: ...6 Function Code Table NICE7000 User Manual 132 ...
Page 135: ...7 Description of Function Codes ...
Page 205: ...8 Troubleshooting ...
Page 224: ...8 Troubleshooting NICE7000 User Manual 222 ...
Page 225: ...9 EMC ...
Page 234: ...9 EMC NICE7000 User Manual 232 ...
Page 237: ......