144
APPX
Appendix 4 Buffer Memory Areas
CH1 Trigger pointer
In CH1 Logging data (Un\G10000 to Un\G19999), the buffer memory address where the data at the time of a hold trigger
event is stored can be checked.
The difference between the buffer memory address where the data at the time of a hold trigger event is stored and the start
address in CH1 Logging data (Un\G10000 to Un\G19999) is stored.
For details on the logging function, refer to the following.
■
Buffer memory address
The following shows the buffer memory address of this area.
When 'CH1 Logging hold request' (Un\G471) is turned on
→
off, 'CH1 Trigger pointer' (Un\G437) is cleared to
0.
CH1 Logging cycle monitor value
This area stores the actual logging cycle which is calculated from the refreshing cycle of data to be logged.
When 'Operating condition setting request' (Un\G70, b9) is turned off
→
on
→
off, the actual logging cycle is stored in Logging
cycle monitor value in the corresponding channel where the logging function is enabled.
For details on the logging function, refer to the following.
The following values are stored in 'CH1 Logging cycle monitor value' (Un\G441 to Un\G442).
■
Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH
Trigger pointer
437
637
837
1037
1237
1437
1637
1837
CH
Trigger pointer (In FX2N allocation mode function)
9061
9062
9063
9064
9065
9066
9067
9068
Buffer memory name
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH
Logging cycle monitor value (s)
441
641
841
1041
1241
1441
1641
1841
CH
Logging cycle monitor value (ms)
442
642
842
1042
1242
1442
1642
1842
CH
Logging cycle monitor value (s) (In FX2N allocation
mode function)
9071
9074
9077
9080
9083
9086
9089
9092
CH
Logging cycle monitor value (ms) (In FX2N allocation
mode function)
9072
9075
9078
9081
9084
9087
9090
9093
b15
b0
s
ms
to
'CH1 Logging cycle monitor value (s)' (Un\G441)
'CH1 Logging cycle monitor value (ms)' (Un\G442)