APPX
Appendix 4 Buffer Memory Areas
115
A
■
Offset/gain setting (Un\G4000 to Un\G9999)
■
Logging data (Un\G10000 to Un\G89999)
In FX2N allocation function mode
: With refresh setting,
: Without refresh setting
Address
Decimal (hexadecimal)
Name
Default
value
Data
type
Auto
refresh
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
4000 to 4131
(FA0H to 1023H)
System area
4132
(1024H)
4134
(1026H)
4136
(1028H)
4138
(102AH)
4140
(102CH)
4142
(102EH)
4144
(1030H)
4146
(1032H)
CH
Offset/gain setting
mode (offset specification)
0
Setting
4133
(1025H)
4135
(1027H)
4137
(1029H)
4139
(102BH)
4141
(102DH)
4143
(102FH)
4145
(1031H)
4147
(1033H)
CH
Offset/gain setting
mode (gain specification)
0
Setting
4148 to 9999
(1034H to 270FH)
System area
Address
Decimal (hexadecimal)
Name
Default
value
Data
type
Auto
refresh
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
10000 to
19999
(2710H
to
4E1FH)
20000 to
29999
(4E20H
to
752FH)
30000 to
39999
(7530H
to
9C3FH)
40000 to
49999
(9C40H
to
C34FH)
50000 to
59999
(C350H
to
EA5FH)
60000 to
69999
(EA60H
to
1116FH)
70000 to
79999
(11170H
to
1387FH)
80000 to
89999
(13880H
to
15F8FH)
CH
Logging data
0
Monitor
Address
Decimal (hexadecimal)
Name
Default
value
Data
type
Auto
refresh
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
0 (0H)
CH1 to 4 Setting Input type/
range
FFFFH
Setting
1 (1H)
CH5 to 8 Setting Input type/
range
FFFFH
Setting
2
(2H)
3
(3H)
4
(4H)
5
(5H)
6
(6H)
7
(7H)
8
(8H)
9
(9H)
CH
Time Average/Count
Average/Moving Average
setting
0
Setting
10
(AH)
11
(BH)
12
(CH)
13
(DH)
14
(EH)
15
(FH)
16
(10H)
17
(11H)
CH
Digital operation value
0000H
Monitor
18 to 25 (12H to 19H)
System area
26 (1AH)
Warning output flag (Process
alarm upper limit/lower limit)
0000H
Monitor
27 (1BH)
Warning output flag (Rate
alarm upper limit/lower limit)
0000H
Monitor
28 (1CH)
Input signal error detection
flag/disconnection detection
flag
0000H
Monitor
29 (1DH)
Latest error code
0
Monitor
30 (1EH)
Module Information
61E4H
Monitor
31 (1FH)
Firmware version
0
Monitor
32 to 59 (20H to 33H)
System area
60 (34H)
Operation mode monitor
0
Monitor
61
(35H)
62
(36H)
63
(37H)
64
(38H)
65
(39H)
66
(3AH)
67
(3BH)
68
(3CH)
CH
Conversion value shift
amount
0
Control
69 (3DH)
Input signals
0
Monitor
70 (3EH)
Output signals
0
Control
71
(3FH)
72
(40H)
73
(41H)
74
(42H)
75
(43H)
76
(44H)
77
(45H)
78
(46H)
CH
Process alarm lower
lower limit value
0
Setting
79, 80 (47H, 48H)
System area
Summary of Contents for MELSEC iQ-F