Appendix 4 Buffer Memory Areas
81
(49H)
82
(4AH)
83
(4BH)
84
(4CH)
85
(4DH)
86
(4EH)
87
(4FH)
88
(50H)
CH
Process alarm upper
upper limit value
0
Setting
89, 90 (51H, 52H)
System area
91
(53H)
92
(54H)
93
(55H)
94
(56H)
95
(57H)
96
(58H)
97
(59H)
98
(5AH)
CH
Rate alarm upper limit
value
100
Setting
99, 100 (5BH, 5CH)
System area
101
(5DH)
102
(5EH)
103
(5FH)
104
(60H)
105
(61H)
106
(62H)
107
(63H)
108
(64H)
CH
Minimum value
0
Monitor
109 (65H)
Minimum value reset request
0
Control
110 (66H)
Minimum value reset
completed flag
0
Monitor
111
(67H)
112
(68H)
113
(69H)
114
(6AH)
115
(6BH)
116
(6CH)
117
(6DH)
118
(6EH)
CH
Maximum value
0
Monitor
119 (6FH)
Maximum value reset request
0
Control
120 (70H)
Maximum value reset
completed flag
0
Monitor
121 (71H)
Latest address of error
history
0
Monitor
122 (72H)
Latest alarm code
0
Monitor
123 (73H)
Latest address of alarm
history
0
Monitor
124 (74H)
Conversion completed flag
0
Monitor
125 (75H)
System area
126, 127 (76H, 77H)
Mode switching setting
0
Setting
128, 129 (78H, 79H)
System area
130 (7AH)
Rate alarm change rate
selection
1
Setting
131, 132 (7BH, 7CH)
System area
133 (7DH)
Input signal error/
Disconnection detection
automatic clear enable/
disable setting
1
Setting
134 to 1000 (7EH to 3E8H)
System area
1001
(3E9H)
1003
(3EBH)
1005
(3EDH)
1007
(3EFH)
1009
(3F1H)
1011
(3F3H)
1013
(3F5H)
1015
(3F7H)
CH
Digital output value
0
Monitor
1002
(3EAH)
1004
(3ECH)
1006
(3EEH)
1008
(3F0H)
1010
(3F2H)
1012
(3F4H)
1014
(3F6H)
1016
(3F8H)
System area
1017 to 1020 (3F9H to 3FCH)
System area
1021
(3FDH)
1022
(3FEH)
1023
(3FFH)
1024
(400H)
1025
(401H)
1026
(402H)
1027
(403H)
1028
(404H)
CH
Conversion status
0
Monitor
1029, 1030 (405H, 406H)
System area
1031
(407H)
1032
(408H)
1033
(409H)
1034
(40AH)
1035
(40BH)
1036
(40CH)
1037
(40DH)
1038
(40EH)
CH
Input type/Range
monitor
0
Monitor
1039, 1040 (40FH, 410H)
System area
1041
(411H)
1042
(412H)
1043
(413H)
1044
(414H)
1045
(415H)
1046
(416H)
1047
(417H)
1048
(418H)
CH
Input type/Range
monitor (Offset/gain setting)
0
Monitor
1049, 1050 (419H, 41AH)
System area
1051
(41BH)
1052
(41CH)
1053
(41DH)
1054
(41EH)
1055
(41FH)
1056
(420H)
1057
(421H)
1058
(422H)
CH
Celsius/Fahrenheit
display monitor
0
Monitor
1059, 1060 (423H, 424H)
System area
1061
(425H)
1062
(426H)
1063
(427H)
1064
(428H)
1065
(429H)
1066
(42AH)
1067
(42BH)
1068
(42CH)
CH
NowSetting user range
base input type monitor
1
Monitor
1069, 1070 (42DH, 42EH)
System area
1071
(42FH)
1072
(430H)
1073
(431H)
1074
(432H)
1075
(433H)
1076
(434H)
1077
(435H)
1078
(436H)
CH
NowSetting user range
base input range monitor
0000H
Monitor
1079, 1080 (437H, 438H)
System area
Address
Decimal (hexadecimal)
Name
Default
value
Data
type
Auto
refresh
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8