FX2N-32DP-IF Profibus-DP Interface Unit
Appendix C:
C-75
C-2-33: FX
2N
-10PG (Motorola Format) - Using 6W-IF -
Requirements:
•
Cyclic data is 6 word inputs and 6 word outputs in every cycle. This data is used for
“Simple Communication 6W-IF”. Further information for the simple commnunication 6W-
IF can be found in section 7.2.1 and 7.2.2.
•
Parameter is 58 bytes.
24
(25th)
acceleration time
Default: 100 (0064 Hex)
Set acceleration time. (BFM #11)
Setting range:
•
Trapezoidal control; 1 to 5000
(0001 to 1388 Hex)
•
S-shaped control; 64 to 5000
(0040 to 1388 Hex)
25
(26th)
deceleration time
Default: 100 (0064 Hex)
Set deceleration time. (BFM #12)
Setting range:
•
Trapezoidal control; 1 to 5000
(0001 to 1388 Hex)
•
S-shaped control; 64 to 5000
(0040 to 1388 Hex)
Table C-65: Cyclic Data of FX2N-10PG 6W-IF (Motorola Format)
Send Data
Receive Data
1st
FROM address
FROM data
2nd
TO data
TO data (read back)
3rd
TO address
TO address (read back)
4th
FROM address
FROM data
5th
TO data
TO data (read back)
6th
TO address
TO address (read back)
Table C-66: FX
2N
-10PG 6W-IF (Motorola Format)
Nr.
Parameter Name
Value Setting List
Description
00
(1st)
pulse rate lower
word
Default: 2000 (07D0 Hex)
Set the lower word for pulse rate.
(BFM #32)
Setting range (BFM #33, #32):
1 to 999999 (00000001 to
000F423F Hex)
01
(2nd)
pulse rate upper
word
Default: 0 (0000 Hex)
Set the upper word for pulse rate.
(BFM #33)
Setting range (BFM #33, #32):
1 to 999999 (00000001 to
000F423F Hex)
02
(3rd)
feed rate lower word Default: 2000 (07D0 Hex)
Set the lower word for feed rate.
(BFM #34)
Setting range (BFM #35, #34):
1 to 999999 (00000001 to
000F423F Hex)
Table C-64: FX
2N
-10PG 6W-IF (Intel Format)
Nr.
Parameter Name
Value Setting List
Description
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......