FX2N-32DP-IF Profibus-DP Interface Unit
Advanced Devices 5
5-6
5.2.3
Profibus-DP Network Status (M8020 ~ M8039 and D8020 ~ D8039)
Table 5.7: Special Auxiliary Relays (M8020 ~ M8039)
Diagnostic
Device
Name
Description
M8020
Setting parameter
When this bit is changed from OFF to ON, the parameter D200
~ D299 (made by the programming tool) is written to special
function blocks’ BFM. After the write is completed, this bit is
turned automatically to OFF.
M8021 ~ M8033
Reserved
M8034
All output disable
All physical switch gear for activating outputs is disabled.
However, for debugging purposes the logical state of these
outputs (D100 ~ D199) can be set, but remain disabled in the
actual module.
M8035 ~ M8039
Reserved
Table 5.8: Special Data Registers (D8020 ~ D8039)
Diagnostic
Device
Name
Description
D8020
(
"
)
Data exchange
status
Data register D8020 contains a status bit for data exchange.
If this is “1”, 32DP-IF is in data exchange mode.
If this is “0”, 32DP-IF is not in data exchange mode.
D8021
(
"
)
Swap byte order
See note 1.
D8022
(
"
)
Length of input
(sent) data in byte
The values held in these devices are copied from the input data
length and output data length setting in the DP-master.
D8023
(
"
)
Length of output
(received) data in
byte
D8024
(
"
)
Baud rate
See note 2.
D8025
(
"
)
Communication
status
See note 3.
D8026
(
8
)
Profibus module
ID (PNO ID code)
PNO-Nr.F232 (Hex)
(This number contains the Profibus module ID number for the
32DP-IF.)
D8027
(
8
)
Slave address
The slave address is set only by the 32DP-IF’s DIP switches.
The slave address value is 0 to 126. The address change by a
Profibus-DP Class 2 master via the network or by a
programming device is not supported.
D8028
Reserved
D8029
(
8
) (
4
)
Error status
See note 4.
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......