FX2N-32DP-IF Profibus-DP Interface Unit
Appendix C:
C-47
*1 home position ret. dir. = home position return direction
*2 Z.P.sig = Zero point signal
*3 zero pt.sig. = zero point signal
C-2-19: FX
2N
-232IF (Intel Format)
Requirements:
•
Cyclic data is 3 word inputs and 3 word outputs in every cycle. These data is used
“Simple Communication 3W-IF”. Further information of the simple commnunication 3W-
IF can be found in section 7.2.1 and 7.2.2.
•
Parameter is 46 bytes.
21
(22nd)
home position
lower word
Default: 0 (0000Hex)
Set lower word for home position.
(BFM #13)
Setting range (BFM #1
4, #13):
-999999 ~ +999999
(FFF0BDC1 ~ 000F423FHex)
22
(23rd)
home position
upper word
Default: 0 (0000Hex)
Set upper word for home position.
(BFM #14)
Setting range (BFM #1
4, #13):
-999999 ~ +999999
(FFF0BDC1 ~ 000F423FHex)
23
(24th)
acc/dec time value
Default: 100 (64Hex)
Set acceleration/deceleration time.
(BFM #15)
Setting range: 50 ~ 5000
(0032 ~ 1388Hex)
Table C-40: Cyclic Data of FX
2N
-232IF (Intel Format)
Send Data
Receive Data
1st
FROM address
FROM data
2nd
TO data
TO data (read back)
3rd
TO address
TO address (read back)
Table C-41: FX
2N
-232IF (Intel Format)
Nr.
Parameter Name
Value Setting List
Description
00
(1st)
data length (1)
7 data bit
Select data length from the
available options. (BFM #0)
8 data bit
01
(2nd)
parity (3)
none
Select parity from the available
options. (BFM #0)
odd
even
02
(3rd)
stop bit (0)
1 stop bit
Select stop bit from the available
options. (BFM #0)
2 stop bit
Table C-39: FX
2N
-1PG (Motorola Format)
Nr.
Parameter Name
Value Setting List
Description
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......