FX2N-32DP-IF Profibus-DP Interface Unit
Appendix C:
C-55
08
(9th)
.. and for channel 2
Default: 0
Set channel 2’s value for Alarm 1.
(BFM #22)
Setting range: -32768 to 32767
09
(10th)
ALARM2 value for
channel 1.
Default: 0
Set channel 1’s value for Alarm 2.
(BFM #14)
Setting range: -32768 to 32767
10
(11th)
.. and for channel 2
Default: 0
Set channel 2’s value for Alarm 2.
(BFM #23)
Setting range: -32768 to 32767
11
(12th)
ALARM3 value for
channel 1.
Default: 0
Set channel 1’s value for Alarm 3.
(BFM #15)
Setting range: -32768 to 32767
12
(13th)
.. and for channel 2
Default: 0
Set channel 2’s value for Alarm 3.
(BFM #24)
Setting range: -32768 to 32767
13
(14th)
ALARM4 value for
channel 1.
Default: 0
Set channel 1’s value for Alarm 4.
(BFM #16)
Setting range: -32768 to 32767
14
(15th)
.. and for channel 2
Default: 0
Set channel 2’s value for Alarm 4.
(BFM #25)
Setting range: -32768 to 32767
15
(16th)
discon. ALARM val.
channel 1.
Default: 0
Set channel 1’s value for the heater
disconnection alarm. (BFM #17)
Setting range: -32768 to 32767
16
(17th)
.. and for channel 2
Default: 0
Set channel 2’s value for the heater
disconnection alarm. (BFM #26)
Setting range: -32768 to 32767
17
(18th)
operation mode
channel 1
monitor
Select operation mode for channel
1 from the available options. (BFM
#32)
m temp. alarm
m temp. alarm + control
18
(19th)
operation mode
channel 2
monitor
Select operation mode for channel
2 from the available options. (BFM
#51)
m temp. alarm
m temp. alarm + control
19
(20th)
control response
par. channel 1
slow
Select the control response
parameter for channel 1 from the
available options. (BFM #36)
medium
fast
20
(21st)
control response
par. channel 2
slow
Select the control response
parameter for channel 2 from the
available options. (BFM #55)
medium
fast
21
(22nd)
temp. rise comp.
soak time
Default: 0
Set the temperature rise completion
soak time. (BFM #80)
Setting range 0 to 3600
Table C-52: FX
2N
-2LC (Intel Format)
Nr.
Parameter Name
Value Setting List
Description
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......