20
(21st)
zero ret. creep
speed
Default: 1000 (03EB Hex)
Set creep speed of home position
return. (BFM #7)
Setting range:
0 to 32767 (0000 to 7FFF Hex)
The range of pulse-converted value
is 0 to 30000 Hz (0000 to 7530
Hex)
21
(22nd)
zero point signal
number
Default: 1 (0001 Hex)
Set number of zero point signal.
(BFM #8)
Setting range:
0 to 32767 (0000 to 7FFF Hex)
22
(23rd)
zero point address
lower word
Default: 0 (0000 Hex)
Set lower word of home position
address. (BFM #9)
Setting range (BFM #10, #9):
-2,147,483,648 to 2,147,483,467
(00000000 to FFFFFFFF Hex)
23
(24th)
zero point address
upper word
Default: 0 (0000 Hex)
Set upper word of home position
address. (BFM #10)
Setting range (BFM #10, #9):
-2,147,483,648 to 2,147,483,467
(00000000 to FFFFFFFF Hex)
24
(25th)
acceleration time
Default: 100 (0064 Hex)
Set acceleration time. (BFM #11)
Setting range:
•
Trapezoidal control; 1 to 5000
(0001 to 1388 Hex)
•
S-shaped control; 64 to 5000
(0040 to 1388 Hex)
25
(26th)
deceleration time
Default: 100 (0064 Hex)
Set deceleration time. (BFM #12)
Setting range:
•
Trapezoidal control; 1 to 5000
(0001 to 1388 Hex)
•
S-shaped control; 64 to 5000
(0040 to 1388 Hex)
Table C-60: FX
2N
-10PG (Intel Format)
Nr.
Parameter Name
Value Setting List
Description
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......