FX2N-32DP-IF Profibus-DP Interface Unit
Appendix C:
C-7
C-2-2:
FX
2N
-4AD Extension Configuration (Motorola Format)
Requirements:
•
Cyclic data is 4 word inputs in every cycle.
•
Parameter is 41 bytes.
Table C-5:
Cyclic Data of FX
2N
-4AD Extension Configuration
(Motorola Format)
Send Data
Receive Data
1st
None
Choose between direct and averaged value ch1
2nd
Choose between direct and averaged value ch2
3rd
Choose between direct and averaged value ch3
4th
Choose between direct and averaged value ch4
Table C-6:
FX
2N
-4AD Extension Configuration (Motorola Format)
Nr.
Parameter Name
Value Setting List
Description
00
(1st)
Channel 1 input
direct input value ch1
Select input value type for channel 1
from the available options (BFM #9 or
BFM #5).
averaged input value ch1
01
(2nd)
Channel 2 input
direct input value ch2
Select input value type for channel 2
from the available options (BFM #10
or BFM #6).
averaged input value ch2
02
(3rd)
Channel 3 input
direct input value ch3
Select input value type for channel 3
from the available options (BFM #11
or BFM #7).
averaged input value ch3
03
(4th)
Channel 4 input
direct input value ch4
Select input value type for channel 4
from the available options (BFM #12
or BFM #8).
averaged input value ch4
04
(5th)
Next parameter
uses EEPROM.
DON'T write parameter to
EEPROM
The 6th parameter uses EEPROM.
Select “writing to EEPROM” setting
from the available options.
write parameter to EEPROM
05
(6th)
..O/G setting
prohibit/permit
permit offset/gain setting
Select prohibit/permit setting of offset/
gain from the available options (BFM
#21).
prohibit offset/gain setting
06
(7th)
RESET/INIT.
MODULE TO
DEFAULT
no reset/initialisation
Select initialize module setting from
the available options (BFM #20).
RESET/INITIALISE MODULE
07
*1
(8th)
VERIFY RESET/
INITIALISE
COMMAND
no reset/initialisation
Select initialize module setting from
the available options (BFM #20).
RESET/INITIALISE MODULE
08
*2
(9th)
A/D conversion
speed
normal speed (15ms/ch)
Select conversion speed from the
available options (BFM #15).
high speed (6ms/ch)
09
(10th)
Next parameter
uses EEPROM.
DON'T write parameter to
EEPROM
The 11th ~13th parameter use
EEPROM. Select “writing to
EEPROM” setting from the available
options.
write parameter to EEPROM
Summary of Contents for FX2N-32DP-IF
Page 4: ...FX2N 32DP IF Profibus DP Interface Unit ii...
Page 6: ...FX2N 32DP IF Profibus DP Interface Unit iv...
Page 12: ...FX2N 32DP IF Profibus DP Interface Unit x...
Page 64: ...FX2N 32DP IF Profibus DP Interface Unit Address Setting 6 6 2 MEMO...
Page 78: ...FX2N 32DP IF Profibus DP Interface Unit User Parameter 7 7 14 MEMO...
Page 80: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostic Message 8 8 2 MEMO...
Page 86: ...FX2N 32DP IF Profibus DP Interface Unit Diagnostics 9 9 6 MEMO...
Page 92: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 6 Figure A 6 Setting Global Parameter...
Page 96: ...FX2N 32DP IF Profibus DP Interface Unit Appendix A A 10 MEMO...
Page 102: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 6 Figure B 6 Setting Global Parameter...
Page 106: ...FX2N 32DP IF Profibus DP Interface Unit Appendix B B 10 MEMO...
Page 192: ...FX2N 32DP IF Profibus DP Interface Unit Appendix C C 86 MEMO...
Page 194: ...FX2N 32DP IF Profibus DP Interface Unit Appendix D D 2 MEMO...
Page 197: ......