FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
258
13 Examples of Wiring for Various Uses
13.4 Hexadecimal Input [HKY Instruction (FNC 71)]
3. Input/output powered extension unit
Example of program
Examples of wiring
M8000
X060
Y050
D100
M0
HKY
COM X060 X061 X062 X063
COM1
Y050 Y051 Y052 Y053
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
External wiring
Transistor output (sink)
Input/output powered
extension unit
FX
2N
-32ET
FX
2N
-48ET
In case of sink wiring
When inputs are used for sink only and outputs are the transistor sink type in the used input/output
powered extension unit
24V X060 X061 X062 X063
+V0 Y050 Y051 Y052 Y053
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
External wiring
Transistor output (source)
0V
S/S
Input/output powered
extension unit
FX
2N
-32ET-ESS/UL
FX
2N
-48ET-ESS/UL
In case of source wiring
When inputs are used for both sink and source and outputs are the transistor source type in the used
input/output powered extension unit
Summary of Contents for FX2-16E series
Page 2: ......
Page 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Page 519: ......