FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
477
A Operation of Special Devices (M8000 -, D8000 -)
A-1 Special Auxiliary Relay (M8000 to M8511)
21
Memor
y
Cas
sette
22
B
attery
A
S
pe
cia
l D
ev
ice
s
(M
8000-
,D800
0-)
B
Instruction Li
st
C
C
haracte
r-c
ode
D
D
isc
onti
nued
mod
els
E
Pr
ec
auti
ons
for
battery
transport
ati
on
F
Handli
ng of
batteries i
n EU
member st
ates
N:N Network
[M]8180
Not used
–
[M]8181
–
[M]8182
–
[M]8183
Data communication error
(Master station)
D8201 to
D8218
[M]8184
Data communication error
(Slave station No.1)
[M]8185
Data communication error
(Slave station No.2)
[M]8186
Data communication error
(Slave station No.3)
[M]8187
Data communication error
(Slave station No.4)
[M]8188
Data communication error
(Slave station No.5)
[M]8189
Data communication error
(Slave station No.6)
[M]8190
Data communication error
(Slave station No.7)
[M]8191
Data communication in execution
[M]8192
Not used
–
[M]8193
–
[M]8194
–
[M]8195
–
[M]8196
–
[M]8197
–
High-Speed Counter Edge Count Specification
M 8198
*1*2
C251, C252, C254: 1/4 edge count
selector
–
M 8199
*1*2
C253, C255, or C253 (OP): 1/4
edge count selector
–
*1. OFF: 1 edge count
ON: 4 edge count
*2. Cleared when PLC switches from RUN to STOP.
Number and
name
Operation and function
Correspond-
ing special
device
Counter Up/down Counter Counting Direction
M 8200
C200
When M8
is ON, the
corresponding C
is
changed to down mode.
• ON: Down count operation
• OFF: Up count operation
–
M 8201
C201
–
M 8202
C202
–
M 8203
C203
–
M 8204
C204
–
M 8205
C205
–
M 8206
C206
–
M 8207
C207
–
M 8208
C208
–
M 8209
C209
–
M 8210
C210
–
M 8211
C211
–
M 8212
C212
–
M 8213
C213
–
M 8214
C214
–
M 8215
C215
–
M 8216
C216
–
M 8217
C217
–
M 8218
C218
–
M 8219
C219
–
M 8220
C220
–
M 8221
C221
–
M 8222
C222
–
M 8223
C223
–
M 8224
C224
–
M 8225
C225
–
M 8226
C226
–
M 8227
C227
–
M 8228
C228
–
M 8229
C229
–
M 8230
C230
–
M 8231
C231
–
M 8232
C232
–
M 8233
C233
–
M 8234
C234
–
High-Speed Counter Up/down Counter Counting Direction
M 8235
C235
When M8
is ON, the
corresponding C
is
changed to down mode.
• ON: Down count operation
• OFF: Up count operation
–
M 8236
C236
–
M 8237
C237
–
M 8238
C238
–
M 8239
C239
–
M 8240
C240
–
M 8241
C241
–
M 8242
C242
–
M 8243
C243
–
M 8244
C244
–
M 8245
C245
–
Number and
name
Operation and function
Correspond-
ing special
device
Summary of Contents for FX2-16E series