FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
44
3 Introduction of Products (Compliant with Overseas Standards)
3.1 List of Products (to be Connected) and Interpretation of Model Names
3. Pulse output and positioning
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
→
For more information on CE, UL and cUL, refer to Page 15 or later.
*1.
Up to 3 units can be connected to one system. Connect them to the end of the system. For details,
refer to FX
2N
-1RM(-E)-SET Handy Manual.
*2.
Please consult with Mitsubishi Electric for information on marine standard practices and the
corresponding types of equipment.
*3.
Products manufactured in and after June, 2006 will comply with the UL and cUL standards.
4. Data link and communication functions
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
* Please consult with Mitsubishi Electric for information on marine standard practices and the
corresponding types of equipment.
→
For more information on CE, UL and cUL, refer to Page 15 or later.
Model name
Description
CE
UL
cUL
Marine
EMC
LVD
FX
2N
-1PG
Pulse output for independent 1-axis control (manual in
Japanese supplied) [100 kHz open collector output]
−
−
−
−
FX
2N
-1PG-E
Pulse output for independent 1-axis control (manual in
English supplied) [100 kHz open collector output]
*2
FX
2N
-10PG
Pulse output for independent 1-axis control
[1 MHz differential line driver output]
−
FX
3U
-20SSC-H
Simultaneous 2-axis (independent 2-axis) control
[Applicable to SSCNET
III
]
*3
−
FX
2N
-10GM
Pulse output for independent 1-axis control
[200 kHz open collector output]
−
FX
2N
-20GM
Pulse output for simultaneous 2-axis (independent 2-
axis) control [200 kHz open collector output]
−
FX
2N
-1RM-SET
*1
1-axis programmable cam switch (manual in Japanese
supplied)
−
−
−
−
FX
2N
-1RM-E-SET
*1
1-axis programmable cam switch (manual in English
supplied)
−
*2
Number of
connected units
Number of input/output
points occupied
Count of number of connected special
function units/blocks
1 unit
8 points
1
2 units
3 units
Model name
Description
CE
UL
cUL
Marine
EMC
LVD
FX
2N
-232IF
1-ch RS-232C non-protocol communication
−
*
FX
3U
-16CCL-M
Master for CC-Link (Compatible with Ver. 2.00 and
Ver. 1.10)
Connectable stations:Remote I/O station,
Remote device station,
Intelligent device station
−
FX
2N
-16CCL-M
Master for CC-Link (Compatible with Ver. 1.10)
Connectable stations:Remote I/O station,
Remote device station
−
−
FX
3U
-64CCL
CC-Link interface (Intelligent device station)
[1 to 4 stations occupied]
−
FX
2N
-32CCL
CC-Link interface (Remote device station)
[1 to 4 stations occupied]
−
−
FX
2N
-64CL-M
Master for CC-Link/LT
−
FX
2N
-16LNK-M
Master for MELSEC I/O Link
−
FX
2N
-32ASI-M
Master for AS-i system
−
−
D
E
D
D
D
D
E
E
E
E
D