19.23.7 Character data input procedure
User messages are entered and assigned to file registers in advance, using GX Developer.
Messages are displayed by a file register
→
data register transfer, with the message being created in place of
the numeric values, etc.
32 data register points are assigned to each message.
1
Starting GX Developer
To start up GX Developer, click the Windows
®
[Start] button, then click [Programs] - [MELSOFT
Application] - [GX Developer].
2
Setting The PLC Model Name
Set the "PLC series" and the "PLC Type" settings as
shown below.
*1.
For Ver. 8.18U to 8.24A of GX Developer, the PLC type
is FX3UC.
3
Parameter Settings
To specify the parameter settings, select "PLC parameter" from the project
data list.
If the project data list does not display, click the toolbar’s [Display] - [Project
data list] items.
Click the "Memory capacity" tab to perform file register assignments.
Required Setting Items
Setting Content
PLC series
FXCPU
PLC Type
FX3U(C)
*1