FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
479
A Operation of Special Devices (M8000 -, D8000 -)
A-1 Special Auxiliary Relay (M8000 to M8511)
21
Memor
y
Cas
sette
22
B
attery
A
S
pe
cia
l D
ev
ice
s
(M
8000-
,D800
0-)
B
Instruction Li
st
C
C
haracte
r-c
ode
D
D
isc
onti
nued
mod
els
E
Pr
ec
auti
ons
for
battery
transport
ati
on
F
Handli
ng of
batteries i
n EU
member st
ates
Positioning
[M]8350
[Y001] Pulse output monitor
(ON: BUSY/ OFF: READY)
–
M 8351
*1
[Y001] Clear signal output function
enable
–
M 8352
*1
[Y001] Zero return direction
specification
–
M 8353
[Y001] Forward limit
–
M 8354
[Y001] Reverse limit
–
M 8355
*1
[Y001] DOG signal logic reverse
–
M 8356
*1
[Y001] Zero point signal logic
reverse
–
M 8357
*1
[Y001] Interrupt signal logic
reverse
–
[M]8358
[Y001] Positioning instruction
activation
–
M 8359
*1
[Y001] Pulse output stop command
–
[M]8360
[Y002] Pulse output monitor
(ON: BUSY/ OFF: READY)
–
M 8361
*1
[Y002] Clear signal output function
enable
–
M 8362
*1
[Y002] Zero return direction
specification
–
M 8363
[Y002] Forward limit
–
M 8364
[Y002] Reverse limit
–
M 8365
*1
[Y002] DOG signal logic reverse
–
M 8366
*1
[Y002] Zero point signal logic
reverse
–
M 8367
*1
[Y002] Interrupt signal logic
reverse
–
[M]8368
[Y002] Positioning instruction
activation
–
M 8369
*1
[Y002] Pulse output stop command
–
[M]8370
*2
[Y003] Pulse output monitor
(ON: BUSY/ OFF: READY)
–
M 8371
*1*2
[Y003] Clear signal output function
enable
–
M 8372
*1*2
[Y003] Zero return direction
specification
–
M 8373
*2
[Y003] Forward limit
–
M 8374
*2
[Y003] Reverse limit
–
M 8375
*1*2
[Y003] DOG signal logic reverse
–
M 8376
*1*2
[Y003] Zero point signal logic
reverse
–
M 8377
*1*2
[Y003] Interrupt signal logic
reverse
–
[M]8378
*2
[Y003] Positioning instruction
activation
–
M 8379
*1*2
[Y003] Pulse output stop command
–
*1. Cleared when PLC switches from RUN to STOP.
*2. Available only when two FX
3U
-2HSY-ADP units are
connected to an FX
3U
PLC.
Number and
name
Operation and function
Correspond-
ing special
device
High-Speed Counter Function
[M]8380
*3
Operation status of C235, C241,
C244, C246, C247, C249, C251,
C252, and C254
–
[M]8381
*3
Operation status of C236
–
[M]8382
*3
Operation status of C237, C242,
and C245
–
[M]8383
*3
Operation status of C238, C248,
C248 (OP), C250, C253, and C255
–
[M]8384
*3
Operation status of C239 and C243
–
[M]8385
*3
Operation status of C240
–
[M]8386
*3
Operation status of C244 (OP)
–
[M]8387
*3
Operation status of C245 (OP)
–
[M]8388
Contact for high-speed counter
function change
–
M 8389
External reset input logic reverse
–
M 8390
Function changeover device for
C244
–
M 8391
Function changeover device for
C245
–
M 8392
Function changeover device for
C248 and C253
–
*3. Cleared when PLC switches from STOP to RUN.
Interrupt Program
[M]8393
Contact for delay time setting
D8393
[M]8394
HCMOV (FNC189):
Drive contact for interrupt program
–
[M]8395
Not used
–
[M]8396
–
[M]8397
–
Ring Counter
M 8398
Ring counter operation
(in 1ms units, 32 bits)
*4
D8398,
D8399
[M]8399
Not used
–
*4. 1ms ring counter (D8399, D8398) will operate after M8398
turns ON.
RS2 (FNC 87) [ch1]
[M]8400
Not used
–
[M]8401
*5
RS2 (FNC 87) [ch1] Send wait flag
–
M 8402
*5
RS2 (FNC 87) [ch1] Send request
D8402
M 8403
*5
RS2 (FNC 87) [ch1]
Receive complete flag
D8403
[M]8404
RS2 (FNC 87) [ch1]
Carrier detection flag
–
[M]8405
*6
RS2 (FNC 87) [ch1]
Data set ready (DSR) flag
–
[M]8406
Not used
–
[M]8407
–
[M]8408
–
M 8409
RS2 (FNC 87) [ch1]
Time-out check flag
–
*5. Cleared when PLC switches from RUN to STOP or when
the RS2 instruction [ch1] is OFF.
*6. Supported in Ver. 2.30 or later
Number and
name
Operation and function
Correspond-
ing special
device
Summary of Contents for FX2-16E series
Page 2: ......
Page 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Page 519: ......