Installation
'19 • HM-T-340
Indoor unit installation
System connection
NOTE
To prevent interference, unscreened communication
and/or sensor cables to external connections must not
be laid closer than 20cm from high voltage cables.
HSB series
Recommended fuse size
The recommended fuse size shown in the following table is
reference value. Choose appropriate size according to local
laws and regulations.
Fuse size
Indoor unit
HSB
60
-W
6A/230V 1AC 50Hz
100
140
Outdoor unit
FDCW
60 20A/230V 1AC 50Hz
71
100 30A/230V 1AC 50Hz
140
Controller
RC-HY
Electric heater
ELK
9M 16A/400V 3NAC 50Hz
Recommended cable size
The recommended cable size shown in the following table is
reference value. Choose appropriate size according to local
laws and regulations.
Cable size
Power - HSB60
-W
3 core
s
, 1.5mm
2
(power cable)
Power - HSB100
Power - HSB140
Power - FDCW60
3 cores, 2.0mm
2
(power cable)
Power - FDCW71
3 cores, 2.5mm
2
(power cable)
Power - FDCW100
Power - FDCW140
3 cores, 6.0mm
2
(power cable)
Power - Controller
3 cores, 1.5mm
2
(power cable)
HSB60
-W
- FDCW60
HSB100 - FDCW71
HSB100 - FDCW100
HSB140 - FDCW140
Indoor unit - Controller 3 cores, 0.5mm
2
, LiYY,EKKX or
equivalent (communication cable)
Power source
In case of HSB series, power source is made to indoor unit,
outdoor unit and controller separately. 230V 1AC 50Hz is
applied.
For indoor unit, incoming supply is connected on AA23-X1
terminal.
AA23-X1
AA23-F3
AA23
AA23-X4
AA23-S3
AA23-X100
For outdoor unit, incoming supply is connected on TB terminal.
See figure on Connection between indoor and outdoor unit.
Connection between indoor and outdoor unit
The communication cable between indoor and outdoor unit is
connected between terminal AA23-X100 in indoor unit and TB
in outdoor unit. Screened 2 cores cable is recommended.
- 98 -
10A/230V 1AC 50Hz
2
0
-W
4
0
-W
#
2 cores, 1.5mm
2
(communication cable)
Summary of Contents for FDCW100VNX-A
Page 7: ... 5 Technical data 19 HM T 340 Technical data ...
Page 36: ... 34 Technical data 19 HM T 340 Dimensions FDCW71VNX A Meaning of symbol ...
Page 38: ... 36 Technical data 19 HM T 340 FDCW140VNX A Meaning of symbol Dimensions ...
Page 41: ... 39 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 42: ... 40 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 43: ... 41 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 44: ... 42 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 45: ... 43 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 46: ... 44 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 47: ... 45 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 48: ... 46 Technical data 19 HM T 340 Electrical circuit diagram ...
Page 49: ... 47 Technical data 19 HM T 340 Electrical circuit diagram Split box HSB60 W ...
Page 50: ... 48 Technical data 19 HM T 340 HSB100 Electrical circuit diagram ...
Page 51: ... 49 Technical data 19 HM T 340 HSB140 Electrical circuit diagram ...
Page 52: ... 50 Technical data 19 HM T 340 Electrical circuit diagram Outdoor units FDCW60VNX A ...
Page 57: ... 55 Technical data 19 HM T 340 Electrical circuit diagram POWER SOURCE RC HY20 W sheet 3 ...
Page 58: ... 56 Technical data 19 HM T 340 Electrical circuit diagram RC HY20 W sheet 4 ...
Page 61: ... 59 Technical data 19 HM T 340 Electrical circuit diagram POWER SOURCE RC HY40 W sheet 3 ...
Page 62: ... 60 Technical data 19 HM T 340 Electrical circuit diagram RC HY40 W sheet 4 ...
Page 64: ... 62 Technical data 19 HM T 340 Electrical circuit diagram RC HY40 W sheet 6 ...
Page 65: ...Installation 19 HM T 340 Installation 63 ...
Page 133: ...Control 19 HM T 340 Control 131 ...
Page 170: ... 168 Service 19 HM T 340 Service ...
Page 263: ... 258 Service 19 HM T 340 Outdoor unit FDCW60VNX FDCW71VNX Component replacement ...
Page 264: ...Service 259 19 HM T 340 FDCW100VNX FDCW140VNX LEK LEK Component replacement ...
Page 290: ... 285 Components 19 HM T 340 Components ...
Page 300: ... 295 Components 19 HM T 340 PT300 Component positions ...
Page 301: ... 296 Components 19 HM T 340 Component positions PT300 PT300 A mm 1634 B mm 743 C mm 673 ...
Page 302: ... 297 Components 19 HM T 340 PT500 Component positions ...
Page 303: ... 298 Components 19 HM T 340 PT500 Component positions PT500 A mm 1835 B mm 897 C mm 832 ...
Page 311: ...THo R THo A THo D Outside units FDCW60VNX 306 Components 19 HM T 340 Piping system ...