5-153
5 Maintenance and Inspection
6) Pressing the [F1] key is kept with the enabling
switch of T/B pressed down. The brake is
released while pressing the key.
Note) In RH-3FRH/6FRH/12FRH/20FRH series,
the brake of the axis shown below repeats
release/lock at the interval in each about
200ms for dropping the J3 axis slowly.
7) With both hands, slowly move the J3 axis in +
(plus) direction , and contact the axis against
the mechanical stopper.
Match the alignment mark of J4 axis in this con
-
dition next.
Go to the following procedure continuously.
When the brake is released, the J3 axis falls by its own weight.
To ensure safety, take appropriate measures such as supporting the axis to avoid the
free fall.
If [F1] key or enable switch of T/B is released, the brakes will be work immediately.
㻶㻟㻌㼍㼤㼕㼟㻌㻔㼟㼔㼍㼒㼠㻕
㻶㻟
㻔㻗㻕
㻺㼛㻚㻞㻌㼍㼞㼙㻌㼏㼛㼢㼑㼞
㻶㻟㻌㼍㼤㼕㼟㻌㻔㼟㼔㼍㼒㼠㻕
㻶㻟
㻔㻗㻕
<RH-3FRH/6FRH/12FRH/20FRH series>
<RH-3FRHR series>
CAUTION