5-151
5 Maintenance and Inspection
5) Input "1" into the J2 axis. Set "0" to other axes.
6) Press the [EXE] key, and display Confirmation
screen.
7) Press the [F1] key, and the origin position is set
up.
8) Setting of the origin is completed.
9) Refer to
Page 162, "5.6.5 Recording the origin
in this manual, and record the origin data
on the origin data seal.
* For the RH-3FRHR series, reinstall the plug into the pinhole after the origin setting. Wrap the sealing tape
around the plug to fix it securely.
to
SPACE
<TOOL>
J1:(
1
)J2:( 0 )J3:( 0 )
J4:( 0 )J5:( 0 )J6:( 0 )
J7:( 0 )J8:( 0 )
CLOSE
123
REL.
<ORIGIN> TOOL
CHANGE TO ORIGIN. OK?
No
123
Yes
<TOOL>
J1:(
1
)J2:( 0 )J3:( 0 )
J4:( 0 )J5:( 0 )J6:( 0 )
J7:( 0 )J8:( 0 )
CLOSE
123
REL.
◇◆◇ Select the axis of origin setting ◇◆◇
Do cursor movement into the parenthesis of each axis by the arrow key. The origin is set only for the axis for
which a "1" is displayed on the screen. If the origin is not to be set, press the [0] key and display a "0".