[8-10 Troubleshooting Inverter Problems ]
52
-
chapter 8
HWE18220_GB
8 Troubleshooting Based on Observed Symptoms
8-10-13
Simple Check on Inverter Circuit Components
Turn off the power to the unit, and leave it turned off for at least 10 minutes. Check that the voltage across pins 1 (+) and
5 (-) of the connector RYPN1 is 20 VDC or less before removing components from the control box.
Part name
Judgment method
IGBT module
Refer to the following page(s). [8-10-14 Troubleshooting Problems with IGBT Module]
Rush current pro-
tection resistor
R1, R5
Measure the resistance between terminals R1 and R5: 22
ȍ
±10%
Electromagnetic
relay
72C
This electromagnetic relay is rated at DC12V and is driven by a coil.
Check the resistance between terminals
DC reactor
DCL
Measure the resistance between terminals: 1
ȍ
or lower (almost 0
ȍ
)
Measure the resistance between terminals and the chassis:
Current sensor
ACCT
Disconnect the wiring connector from CNCT2, and measure the inter-teminal resistance: 280
ȍ
±30
ȍ
Between pins 1 and 2 (U-phase), pins 3 and 4 (W-phase)
4
3
2
1
Coil
Contact
INV board
X901, X902
Across pins 1-2
INV board
FT-P1 and FT-P2
*Faston terminal removed
160Ω ± 10%
INV board CNRY
Open: ∞
INV board CNRY
At a voltage input of
12 VDC: 0Ω
Check point
INV35Y, INV42Y
Checking criteria
INV board
X101, X102, X103
Across pins 1-2
INV board
FT100 and FT101
*Faston terminal removed
INV37YC
INV board
X901, X902, X903
Across pins 1-2
INV board
FT-P1 and FT-P2
*Faston terminal removed
INV38
INV board
X100, X101, X102, X103
Across pins 1-2
INV board
FT100 and FT101
*Faston terminal removed
INV39C
INV board
SC-U
ACCT-U
*Check ACCT wiring for correct phase and direction.
ACCT-W
SC-V
SC-W
U
W
Summary of Contents for PURY-HP144
Page 1: ......
Page 9: ...viii ...
Page 13: ...HWE18220_GB ...
Page 29: ...HWE18220_GB ...
Page 77: ...HWE18220_GB ...
Page 95: ...HWE18220_GB ...
Page 125: ...HWE18220_GB ...
Page 153: ...HWE18220_GB ...
Page 163: ...HWE18220_GB ...
Page 343: ...HWE18220_GB ...
Page 361: ...HWE18220_GB ...
Page 398: ......