1 - 26
1. FUNCTIONS AND CONFIGURATION
(6) MR-J3-700B(4)-RJ006
MR Configurator
Personal
computer
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
CN5
CN3
CN1A
CN1B
CN2
CN2L
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
Line noise
filter
(FR-BSF01)
Power factor
improving DC
reactor
(FR-BEL-(H))
Regenerative option
Servo motor
(Note 3)
Power supply
Servo amplifier
(Note 2)
Load side encoder
R S T
L
11
L
21
L
3
L
2
L
1
U V W
P C
P
1
P
2
(Note 1)
(Note 1)
Note 1. The AC reactor can be also used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1
and P
2
.
2. For the configuration of the ABZ-phase pulse train interface or serial communication specification linear encoder/rotary encoder,
refer to section 1.10.
3. Refer to section 1.3 for the power supply specification.
Summary of Contents for MR-J3-B-RJ006
Page 15: ...A 14 MEMO ...
Page 19: ...4 MEMO ...
Page 65: ...2 18 2 SIGNALS AND WIRING MEMO ...
Page 119: ...4 22 4 OPERATION AND FUNCTIONS MEMO ...
Page 145: ...6 6 6 TROUBLESHOOTING MEMO ...
Page 155: ...7 10 7 OUTLINE DRAWINGS MEMO ...
Page 165: ...SH NA 030056 C ...