App. - 4
APPENDIX
App. 4 MR-J3-200B-RJ006 servo amplifiers manufactured before March 2008
Connectors (CNP1, CNP2, and CNP3) and appearance of MR-J3-200B-RJ006 servo amplifier have been
changed from April 2008 production. The difference between new MR-J3-200B-RJ006 servo amplifier and
existing servo amplifier is described in this appendix. Sections within parentheses in the following sections
indicate corresponding sections of the instruction manual.
App. 4.1 Parts identification (1.8.1 Parts identification)
SW2
8
7
6
5
4
3
2 1 0 F
E
D
C
B
A
9
2
Display
The 3-digit, seven-segment LED shows the servo
status and alarm number.
Rotary axis setting switch (SW1)
Used to set the axis No. of servo amplifier.
SW1
Test operation select switch (SW2-1)
Used to perform the test operation
mode by using MR Configurator.
Spare (Be sure to set to the "Down"
position).
Main circuit power supply connector (CNP1)
Connect the input power supply.
USB communication connector (CN5)
Connect the personal computer.
I/O signal connector (CN3)
Used to connect digital I/O signals.
More over an analog monitor is output.
Control circuit connector (CNP2)
Connect the control circuit power supply/regenerative
option.
SSCNET cable connector (CN1A)
Used to connect the servo system controller or the front
axis servo amplifier.
SSCNET cable connector (CN1B)
Used to connect the rear axis servo amplifier. For the final
axis, puts a cap.
Servo motor power connector (CNP3)
Connect the servo motor.
Encoder connector (CN2)
Used to connect the servo motor encoder.
Charge lamp
Lit to indicate that the main circuit is charged. While this
lamp is lit, do not reconnect the cables.
Connector for manufacturer setting (CN4)
Not used for this servo amplifier.
Load side encoder connector (CN2L)
Connect the load side encoder.
Battery holder
Not used for this servo amplifier.
Protective earth (PE) terminal ( )
Ground terminal.
Rating plate
1
Refer to the
MR-J3- B
Servo
Amplifier
Instruction
Manual.
Refer to the
MR-J3- B
Servo
Amplifier
Instruction
Manual.
Section 2.2
Section 2.3
Section 2.4
Section 2.2
Refer to the
MR-J3- B
Servo
Amplifier
Instruction
Manual.
Section 2.2
Chapter 3
Section 2.2
Section 1.6
Name/Application
Detailed
explanation
7
9
6
8
5
4
3
2
1
0
F
E
D
C
B
A
1
2
ON 4E
SW1
SW2
TEST
Cooling fan
Fixed part
(3 places)
Summary of Contents for MR-J3-B-RJ006
Page 15: ...A 14 MEMO ...
Page 19: ...4 MEMO ...
Page 65: ...2 18 2 SIGNALS AND WIRING MEMO ...
Page 119: ...4 22 4 OPERATION AND FUNCTIONS MEMO ...
Page 145: ...6 6 6 TROUBLESHOOTING MEMO ...
Page 155: ...7 10 7 OUTLINE DRAWINGS MEMO ...
Page 165: ...SH NA 030056 C ...