10 USING A LINEAR SERVO MOTOR
10.4 Basic functions
369
10
10.4
Basic functions
Homing [G] [WG]
Precautions
• The incremental linear encoder and the absolute position linear encoder have different reference home positions at
homing.
• For the incremental linear encoder, a home position (reference mark) of the linear encoder is necessary in the homing
direction.
• To execute homing securely in the following example, move the linear servo motor to LSN with an operation such as the
JOG operation, then start homing.
LSN
LSP
Returnable area: Homing is possible when homing
is started from this area.
Non-returnable area: Homing is not possible when homing
is started from this area.
Dog
Homing direction
Home position of linear encoder (reference mark)