6 OPTIONS AND PERIPHERAL EQUIPMENT
6.4 Multifunction regeneration converter (FR-XC-(H))
209
6
Fuses (between P/+ and P4, between N/- and N-)
The following table shows the recommended fuses which are to be installed between the FR-XC-(H) and servo amplifier.
*1 Manufacturer: Mersen Fma Japan KK
Service inquiries: Sun-wa Technos Corp.
Molded-case circuit breakers/earth-leakage current breakers and magnetic contactors
Recommended molded-case circuit breakers/earth-leakage current breakers and magnetic contactors are listed in the table
below.
■
200 V class
*1 Models in parentheses can be used when the rated capacity of multifunction regeneration converter
≥
total capacity of connected servo
amplifiers × 2.
■
400 V class
*1 Models in parentheses can be used when the rated capacity of multifunction regeneration converter
≥
total capacity of connected servo
amplifiers × 2.
Servo amplifier capacity [kW]
200 V class
400 V class
Fuse rating [A]
Model
Fuse rating [A]
0.1
20
6.900CPGR10.38 0020
0.2
20
6.900CPGR10.38 0020
0.4
25
6.900CPGR10.38 0025
0.6
25
6.900CPGR10.38 0025
20
6.900CPGR10.38 0020
0.75
30
6.900CPGR10.38 0030
1
32
6.900CPGR10.38 0032
20
6.900CPGR10.38 0020
2
63
6.9URD30TTF 0063
25
6.900CPGR10.38 0025
3.5
80
6.9URD30TTF 0080
63
6.9URD30TTF0063
5
160
6.9URD30TTF 0160
7
200
6.9URD30TTF 0200
Item
FR-XC-_
7.5K
11K
15K
22K
30K
37K
55K
Molded-case circuit breaker
or earth-leakage current
breaker
100AF 60A
(30AF 30A)
100AF 75A
(50AF 50A)
225AF 125A
(100AF 75A)
225AF 175A
(100AF 100A)
225AF 225A
(125AF 125A)
400AF 250A
(125AF 125A)
400AF 400A
(225AF 175A)
Magnetic contactor
S-T35
(S-T21)
S-T50
(S-T35)
S-T65
(S-T50)
S-T100
(S-T65)
S-N125
(S-T80)
S-N150
(S-T100)
S-N220
(S-N125)
Item
FR-XC-H_
7.5K
11K
15K
22K
30K
37K
55K
Molded-case circuit breaker
or earth-leakage current
breaker
30AF 30A
(30AF 15A)
50AF 50A
(30AF 20A)
100AF 60A
(30AF 30A)
100AF 100A
(50AF 50A)
225AF 125A
(60AF 60A)
225AF 150A
(100AF 75A)
225AF 200A
(100AF 100A)
Magnetic contactor
S-T21
S-T25
(S-T21)
S-T35
(S-T21)
S-T50
(S-T25)
S-T65
(S-T35)
S-T80
(S-T50)
S-N125
(S-T65)
Summary of Contents for MELSERVO-J5 MR-J5-G Series