Parameters according to purposes
4.3
Adjustment of the output torque (current) of the motor
67
4.3.1
Manual torque boost (Pr. 0, Pr. 46) ........................................................................................................................... 67
4.3.2
Simple magnetic flux vector control (Pr.80, Pr.90).................................................................................................... 68
4.3.3
Slip compensation (Pr. 245 to Pr. 247) ..................................................................................................................... 69
4.3.4
Stall prevention operation
(Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66, Pr. 148, Pr. 149, Pr. 154, Pr. 156, Pr. 157) .................................................. 70
4.3.5
Multiple rating (Pr.570)............................................................................................................................................... 75
4.4
Limiting the output frequency
76
4.4.1
Maximum/minimum frequency (Pr. 1, Pr. 2, Pr. 18) ................................................................................................. 76
4.4.2
Avoiding mechanical resonance points (Frequency jump) (Pr. 31 to Pr. 36).......................................................... 77
4.5
V/F pattern
78
4.5.1
Base frequency, voltage (Pr. 3, Pr. 19, Pr. 47) ......................................................................................................... 78
4.5.2
Load pattern selection (Pr. 14)................................................................................................................................... 80
4.5.3
Adjustable 5 points V/F (Pr. 71, Pr. 100 to Pr. 109).................................................................................................. 81
4.6
Frequency setting by external terminals
82
4.6.1
Multi-speed setting operation (Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239) .................................................. 82
4.6.2
Jog operation (Pr. 15, Pr. 16)..................................................................................................................................... 84
4.6.3
Input compensation of multi-speed and remote setting (Pr. 28) .............................................................................. 86
4.6.4
Remote setting function (Pr. 59)................................................................................................................................ 87
4.7
Setting of acceleration/deceleration time and
acceleration/deceleration pattern
90
4.7.1
Setting of the acceleration and deceleration time (Pr.7, Pr.8, Pr.20, Pr.21, Pr.44, Pr.45)...................................... 90
4.7.2
Starting frequency and start-time hold function (Pr.13, Pr.571)............................................................................... 92
4.7.3
Acceleration/deceleration pattern (Pr.29, Pr.140 to Pr.143)..................................................................................... 93
4.8
Selection and protection of a motor
95
4.8.1
Motor protection from overheat (Electronic thermal relay function) (Pr. 9, Pr. 51).................................................. 95
4.8.2
Applied motor (Pr. 71) ................................................................................................................................................ 99
4.9
Motor brake and stop operation
100
4.9.1
DC injection brake (Pr. 10 to Pr. 12)........................................................................................................................ 100
4.9.2
Selection of a regenerative brake and DC feeding (Pr. 30, Pr. 70)........................................................................ 102
4.9.3
Stop selection (Pr. 250)............................................................................................................................................ 107
4.9.4
Output stop function (Pr.522)................................................................................................................................... 108
4.10 Function assignment of external terminal and control
110
4.10.1
Input terminal function selection (Pr. 178 to Pr. 189).............................................................................................. 110
4.10.2
Inverter output shutoff signal (MRS signal, Pr. 17) ................................................................................................. 112
4.10.3
Condition selection of function validity by the second function selection signal (RT) (RT signal, Pr. 155) .......... 113
4.10.4
Start signal selection (STF, STR, STOP signal, Pr. 250)....................................................................................... 114
4.10.5
Output terminal function selection (Pr. 190 to Pr. 196)........................................................................................... 116
4.10.6
Detection of output frequency (SU, FU, FU2 signal, Pr. 41 to Pr. 43, Pr. 50) ....................................................... 120
4.10.7
Output current detection function
(Y12 signal, Y13 signal, Pr. 150 to Pr. 153, Pr. 166, Pr. 167)................................................................................ 121
4.10.8
Remote output function (REM signal, Pr. 495 to Pr. 497) ...................................................................................... 123
4.10.9
Pulse train output of output power (Y79 signal, Pr. 799)........................................................................................ 124
4.11 Monitor display and monitor output signal
125
4.11.1
Speed display and speed setting (Pr. 37, Pr. 144) ................................................................................................. 125
4.11.2
DU/PU monitor display selection
(Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)........................................................ 126
4.11.3
CA, AM terminal function selection (Pr.55, Pr.56, Pr.867, Pr.869) ........................................................................ 131
4.11.4
Terminal CA, AM calibration
(Calibration parameter C0 (Pr. 900), C1 (Pr. 901), C8 (Pr.930) to C11 (Pr. 931))................................................ 133
4.12 Operation selection at power failure and instantaneous power failure
136
4.12.1
Automatic restart after instantaneous power failure / flying start
(Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr. 299, Pr. 611)............................................................................................... 136
4.12.2
Power failure-time deceleration-to-stop function (Pr. 261 to Pr. 266 )................................................................... 140
4.13 Operation setting at fault occurrence
143
4.13.1
Retry function (Pr. 65, Pr. 67 to Pr. 69) ................................................................................................................... 143
4.13.2
Fault code output selection (Pr.76).......................................................................................................................... 145
4.13.3
Input/output phase loss protection selection (Pr. 251, Pr. 872).............................................................................. 146