57
Param
e
te
r
List
Parameter list
4
PA
R
A
M
E
T
E
R
S
Autom
a
tic
re
st
ar
t f
un
ct
io
ns
57
Restart coasting time
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
0.1s
9999
136
58
Restart cushion time
0 to 60s
0.1s
1s
136
59
Remote function selection
0, 1, 2, 3, 11, 12, 13
1
0
87
60
Energy saving control selection
0, 4, 9
1
0
147
65
Retry selection
0 to 5
1
0
143
66
Stall prevention operation reduction
starting frequency
0 to 400Hz
0.01Hz
50Hz
70
Re
tr
y
67
Number of retries at fault occurrence
0 to 10, 101 to 110
1
0
143
68
Retry waiting time
0 to 10s
0.1s
1s
143
69
Retry count display erase
0
1
0
143
70
Special regenerative brake duty
0 to 10%
0.1%
0%
102
71
Applied motor
0, 1, 2, 20
1
0
99
72
PWM frequency selection
0 to 15/0 to 6, 25
1
2
153
73
Analog input selection
0 to 7, 10 to 17
1
1
155
74
Input filter time constant
0 to 8
1
1
161
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17,
100 to 103, 114 to 117
1
14
169
76
Fault code output selection
0, 1, 2
1
0
145
77
Parameter write selection
0, 1, 2
1
0
172
78
Reverse rotation prevention selection
0, 1, 2
1
0
173
79
Operation mode selection
0, 1, 2, 3, 4, 6, 7
1
0
175
Si
m
pl
e
m
agn
et
ic
flu
x
ve
cto
r c
on
tro
l
80
Motor capacity(Simple magnetic flux
vector control)
0.4 to 55kW, 9999/
0 to 3600kW, 9999
0.01/0.1kW
9999
68
90
Motor constant (R1)
0 to 50
:
, 9999/
0 to 400m
:
, 9999
0.001
:
/
0.01m
:
9999
68
Ad
ju
st
ab
le
5
poi
nt
s
V/
F
100
V/F1(first frequency)
0 to 400Hz, 9999
0.01Hz
9999
81
101
V/F1(first frequency voltage)
0 to 1000V
0.1V
0V
81
102
V/F2(second frequency)
0 to 400Hz, 9999
0.01Hz
9999
81
103
V/F2(second frequency voltage)
0 to 1000V
0.1V
0V
81
104
V/F3(third frequency)
0 to 400Hz, 9999
0.01Hz
9999
81
105
V/F3(third frequency voltage)
0 to 1000V
0.1V
0V
81
106
V/F4(fourth frequency)
0 to 400Hz, 9999
0.01Hz
9999
81
107
V/F4(fourth frequency voltage)
0 to 1000V
0.1V
0V
81
108
V/F5(fifth frequency)
0 to 400Hz, 9999
0.01Hz
9999
81
109
V/F5(fifth frequency voltage)
0 to 1000V
0.1V
0V
81
PU
c
onn
ec
to
r
co
m
m
uni
cat
io
n
117
PU communication station number
0 to 31
1
0
194
118
PU communication speed
48, 96, 192, 384
1
192
194
119
PU communication stop bit length
0, 1, 10, 11
1
1
194
120
PU communication parity check
0, 1, 2
1
2
194
121
Number of PU communication retries
0 to 10, 9999
1
1
194
122
PU communication check time
interval
0, 0.1 to 999.8s, 9999
0.1s
9999
194
123
PU communication waiting time
setting
0 to 150ms, 9999
1
9999
194
124
PU communication CR/LF selection
0, 1, 2
1
1
194
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
50Hz
162
Function Parameters
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Summary of Contents for F700
Page 327: ...318 MEMO ...
Page 340: ...331 MEMO ...