328
557
Current average value monitor signal
output reference current
39
B9
5
{
{
{
563
Energization time carrying-over times
3F
BF
5
u
u
u
564
Operating time carrying-over times
40
C0
5
u
u
u
570
Multiple rating setting
46
C6
5
{
u
u
571
Holding time at a start
47
C7
5
{
{
{
573
4mA input check selection
49
C9
5
{
{
{
575
Output interruption detection time
4B
CB
5
{
{
{
576
Output interruption detection level
4C
CC
5
{
{
{
577
Output interruption cancel level
4D
CD
5
{
{
{
578
Auxiliary motor operation selection
4E
CE
5
{
{
{
579
Motor connection function selection
4F
CF
5
{
{
{
580
MC switching interlock time
50
D0
5
{
{
{
581
Start waiting time
51
D1
5
{
{
{
582
Auxiliary motor connection-time
deceleration time
52
D2
5
{
{
{
583
Auxiliary motor disconnection-time
acceleration time
53
D3
5
{
{
{
584
Auxiliary motor 1 starting frequency
54
D4
5
{
{
{
585
Auxiliary motor 2 starting frequency
55
D5
5
{
{
{
586
Auxiliary motor 3 starting frequency
56
D6
5
{
{
{
587
Auxiliary motor 1 stopping frequency
57
D7
5
{
{
{
588
Auxiliary motor 2 stopping frequency
58
D8
5
{
{
{
589
Auxiliary motor 3 stopping frequency
59
D9
5
{
{
{
590
Auxiliary motor start detection time
5A
DA
5
{
{
{
591
Auxiliary motor stop detection time
5B
DB
5
{
{
{
592
Traverse function selection
5C
DC
5
{
{
{
593
Maximum amplitude amount
5D
DD
5
{
{
{
594
Amplitude compensation amount
during deceleration
5E
DE
5
{
{
{
595
Amplitude compensation amount
during acceleration
5F
DF
5
{
{
{
596
Amplitude acceleration time
60
E0
5
{
{
{
597
Amplitude deceleration time
61
E1
5
{
{
{
611
Acceleration time at a restart
0B
8B
6
{
{
{
653
Speed smoothing control
35
B5
6
{
{
{
654
Speed smoothing cutoff frequency
36
B6
6
{
{
{
799
Pulse increment setting for output
power
63
E3
7
{
{
{
867
AM output filter
43
C3
8
{
{
{
869
Current output filter
45
C5
8
{
{
{
872
Input phase loss protection selection
48
C8
8
{
{
{
882
Regeneration avoidance operation
selection
52
D2
8
{
{
{
883
Regeneration avoidance operation
level
53
D3
8
{
{
{
884
Regeneration avoidance at
deceleration detection sensitivity
54
D4
8
{
{
{
885
Regeneration avoidance
compensation frequency limit value
55
D5
8
{
{
{
886
Regeneration avoidance voltage gain
56
D6
8
{
{
{
888
Free parameter 1
58
D8
8
{
u
u
889
Free parameter 2
59
D9
8
{
u
u
891
Cumulative power monitor digit shifted
times
5B
DB
8
{
{
{
892
Load factor
5C
DC
8
{
{
{
893
Energy saving monitor reference
(motor capacity)
5D
DD
8
{
{
{
Parameter
Name
Instruction Code
* 1
Parameter
Copy
*2
Parameter
Clear
*2
All Parameter
Clear
*2
Read
Write
Extended
Summary of Contents for F700
Page 327: ...318 MEMO ...