266
Check and clear of the faults history
(2) Clearing procedure
POINT
· The faults history can be cleared by setting "1" in
Er.CL Faults history clear
.
1.
Screen at powering on
The monitor display appears.
Display
Operation
2.
Press to choose the parameter
setting mode.
3.
Turn until (faults history clear)
appears.
Flicker ··· Faults history clear complete!!
6.
Press to set.
4.
Press to read the present set value.
" "(initial value) appears.
· Press to show the setting again.
· Press twice to show the next parameter.
· Press to read another parameter.
5.
Turn to change
it to the setting value " ".
The parameter
number previously
read appears.
Summary of Contents for F700
Page 327: ...318 MEMO ...
Page 340: ...331 MEMO ...