70
Parameter list
C
om
m
u
ni
ca
tion
549
Protocol selection
0, 1, 2
1
1
550
NET mode operation command
source selection
0, 1, 9999
1
9999
551
PU mode operation command source
selection
1, 2
1
2
PID
con
tr
ol
553
PID deviation limit
0 to 100.0%, 9999
0.1%
9999
554
PID signal operation selection
0 to 3, 10 to 13
1
0
C
ur
re
nt
av
er
ag
e
mo
ni
to
r
555
Current average time
0.1 to 1.0s
0.1s
1s
556
Data output mask time
0.0 to 20.0s
0.1s
0s
557
Current average value monitor signal
output reference current
0 to 500A/0 to 3600A
0.01/0.1A
Rated
inverter
current
⎯
563
Energization time carrying-over times
(0 to 65535)
1
0
⎯
564
Operating time carrying-over times
(0 to 65535)
1
0
M
ult
ip
le
ra
tin
g
570
Multiple rating setting
0, 1
1
0
⎯
571
Holding time at a start
0.0 to 10.0s, 9999
0.1s
9999
⎯
573
4mA input check selection
1, 2, 3, 4, 9999
1
9999
P
ID
co
nt
ro
l
575
Output interruption detection time
0 to 3600s, 9999
0.1s
1s
576
Output interruption detection level
0 to 400Hz
0.01Hz
0Hz
577
Output interruption cancel level
900 to 1100%
0.1%
1000%
P
ump
fu
nc
tio
n
578
Auxiliary motor operation selection
0 to 3
1
0
579
Motor connection function selection
0 to 3
1
0
580
MC switching interlock time
0 to 100s
0.1s
1s
581
Start waiting time
0 to 100s
0.1s
1s
582
Auxiliary motor connection-time
deceleration time
0 to 3600/360s, 9999
0.1/0.01s
1s
583
Auxiliary motor disconnection-time
acceleration time
0 to 3600/360s, 9999
0.1/0.01s
1s
584
Auxiliary motor 1 starting frequency
0 to 400Hz
0.01Hz
60Hz
585
Auxiliary motor 2 starting frequency
0 to 400Hz
0.01Hz
60Hz
586
Auxiliary motor 3 starting frequency
0 to 400Hz
0.01Hz
60Hz
587
Auxiliary motor 1 stopping frequency
0 to 400Hz
0.01Hz
0Hz
588
Auxiliary motor 2 stopping frequency
0 to 400Hz
0.01Hz
0Hz
589
Auxiliary motor 3 stopping frequency
0 to 400Hz
0.01Hz
0Hz
590
Auxiliary motor start detection time
0 to 3600s
0.1s
5s
591
Auxiliary motor stop detection time
0 to 3600s
0.1s
5s
⎯
611
Acceleration time at a restart
0 to 3600s, 9999
0.1s
5/15s
S
p
ee
d
sm
oo
th
in
g
co
nt
ro
l
653
Speed smoothing control
0 to 200%
0.1%
0
654
Speed smoothing cutoff frequency
0 to 120Hz
0.01Hz
20Hz
⎯
665
Regeneration avoidance frequency
gain
0 to 200%
0.1%
100%
Function Parameters
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Summary of Contents for 700 Series
Page 11: ...MEMO ...
Page 23: ...12 MEMO ...
Page 341: ...330 MEMO ...
Page 365: ...354 MEMO ...
Page 379: ...368 MEMO ...
Page 397: ...386 MEMO ...
Page 414: ...403 MEMO ...