229
Communication operation and setting
4
List of calibration parameters
[Special monitor selection No.]
for details of the monitor description.
....
Specifications differ according to the date assembled.
to check the SERIAL number.
*1
The setting depends on capacities. (FR-F720-02330 (FR-F740-01160) or less/FR-F720-03160 (FR-F740-01800) or more)
*2
Input terminal monitor details
*3
Output terminal monitor details
*5
Option input terminal 1 monitor details (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
*6
Option input terminal 2 monitor details (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
*7
Option output terminal monitor details (output terminal status of FR-A7AY)-all terminals are OFF when an option is not fitted
b15
b0
⎯
⎯
⎯
⎯
CS
RES
STOP
MRS
JOG
RH
RM
RL
RT
AU
STR
STF
b15
b0
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
ABC2
ABC1
FU
OL
IPF
SU
RUN
*4
When
Pr.37
= "1 to 9998" or
Pr. 144
= "2 to 10, 102 to 110," the unit is an integral value (one increment).
)
b15
b0
X15
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X0
b15
b0
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
⎯
DY
b15
b0
⎯
⎯
⎯
⎯
⎯
⎯
RA3
RA2
RA1
Y6
Y5
Y4
Y3
Y2
Y1
Y0
Para
meter
Name
Instruction code
Read
Write
Extended
C2
(902)
Terminal 2 frequency
setting bias frequency
5E
DE
1
C3
(902)
Terminal 2 frequency
setting bias
5E
DE
1
125
(903)
Terminal 2 frequency
setting gain frequency
5F
DF
1
C4
(903)
Terminal 2 frequency
setting gain
5F
DF
1
C5
(904)
Terminal 4 frequency
setting bias frequency
60
E0
1
C6
(904)
Terminal 4 frequency
setting bias
60
E0
1
126
(905)
Terminal 4 frequency
setting gain frequency
61
E1
1
C7
(905)
Terminal 4 frequency
setting gain
61
E1
1
C8
(930) Current output bias signal
1E
9E
9
C9
(930) Current output bias current
1E
9E
9
C10
(931) Current output gain signal
1F
9F
9
C11
(931) Current output gain current
1F
9F
9
C42
(934) PID display bias coefficient
22
A2
9
C43
(934)
PID display bias analog
value
22
A2
9
C44
(935) PID display gain coefficient
23
A3
9
C45
(935)
PID display gain analog
value
23
A3
9
Para
meter
Name
Instruction code
Read
Write
Extended
Data
Description
Unit
H01 Output frequency/speed
0.01Hz/1
H02 Output current
0.01A/0.1A
H03 Output voltage
0.1V
H05 Frequency setting value/speed setting
0.01Hz/1
H06 Running speed
1r/min
H08 Converter output voltage
0.1V
H09 Regenerative brake duty
0.1%
H0A Electronic thermal relay function load factor
0.1%
H0B Output current peak value
0.01A/0.1A
H0C Converter output voltage peak value
0.1V
H0D Input power
0.01kW/0.1kW
H0E Output power
0.01kW/0.1kW
⎯
⎯
H11 Load meter
0.1%
H14 Cumulative energization time
1h
H17 Actual operation time
1h
H18 Motor load factor
0.1%
H19 Cumulative power
1kWh
H32 Power saving effect
Variable
H33 Cumulative saving power
Variable
H34 PID set point
0.1%
H35 PID measured value
0.1%
H36 PID deviation
0.1%
H3A Option input terminal status 1
⎯
H3B Option input terminal status 2
⎯
H3C Option output terminal status
⎯
H4D
32-bit cumulative power
(lower 16-bit)
1kWh
H4E
32-bit cumulative power
(upper 16-bit)
1kWh
H4F
32-bit cumulative power
(lower 16-bit)
H50
32-bit cumulative power
(upper 16-bit)
Data
Description
Unit