(3) The following functions and two plug-in options can be used with the inverter produced in June 2010 or later.
Check the serial number printed on the rating plate or on package.
(4) BACnet MS/TP protocol and the following functions can be used with the inverter produced in August 2010 or
later. Check the serial number printed on the rating plate or on package.
Item
Changed Functions
Added parameter setting values
Pr. 30 Regenerative function selection
setting value "100, 101, 120, 121"
Pr. 54 CA terminal function selection and 158 AM terminal function selection
setting value
"70"
Pr. 128 PID action selection
setting value "70 to 101"
Pr. 178 to Pr. 189 (input terminal function selection)
setting value
"50, 51, 77 and 78"
Pr. 190 to Pr. 196 (output terminal function selection)
setting value "49 to 54, 67, 149 to 154,
167"
Pr.573 4mA input check selection
setting range "2, 3, 4"
Added parameters
Pr. 147, Pr. 296, Pr. 297, Pr. 414, Pr. 415, Pr. 498, Pr. 502, Pr. 505 to Pr. 515 , Pr. 665, Pr. 753
to Pr. 769, Pr. 774 to Pr. 779, Pr. 826 to Pr. 865, Pr. 870, Pr. 997, Pr. 999, Pr.CH, AUTO,
Changed parameter setting ranges
Pr. 263
Subtraction starting frequency
setting range "0 to 120Hz, 9999" to "0 to 400Hz,
9999"
Pr. 885
Regeneration avoidance compensation frequency limit value
setting range "0 to
10Hz, 9999" to "0 to 30Hz, 9999"
Mitsubishi inverter protocol
(computer link communication)
⋅
Multi-command
⋅
Model information monitor
⋅
Cumulative power (32-bit) for a special monitor
Modbus-RTU communication
⋅
Model information monitor
⋅
Cumulative power (32-bit) for a real time monitor
Error message
⋅
LOCd Password locked
⋅
E.2
Option fault
⋅
E.OP2 Communication option fault
⋅
E.PCH Pre-charge stop
⋅
E.LCI 4mA
input fault
Item
Changed Functions
Added parameter setting values
Pr. 52 DU/PU main display data selection
setting value "67, 81 to 86"
Pr. 54 CA terminal function selection
setting value "67, 85"
Pr. 158 AM terminal function selection
setting value "67, 86"
Pr. 190 to Pr. 196 (output terminal function selection)
setting value "82 and 182"
Pr. 331 RS-485 communication station number
setting range "0 to 127"
Pr. 332 RS-485 communication speed
setting range "768"
Pr. 549 Protocol selection
setting range "2"
Pr. 774 to Pr. 776 PU/DU monitor selection 1 to 3
setting range "67, 81 to 86"
Added parameters
Pr. 390, Pr. 726 to Pr. 729