39
Connection of stand-alone option units
<Inserting the CN8 connector>
Make cuts in rubber bush of the upper portion of the inverter and lead a cable.
1) Make cuts in the rubber bush for leading the CN8 connector cable with a nipper or cutter knife.
2) Insert a connector on the MT-BU5 side through a rubber bush to connect to a connector on the inverter side.
CAUTION
Clamp the CN8 connector cable on the inverter side with a wire clamp securely.
♦
Parameters referred to
Pr. 30 Regenerative function selection
Pr. 70 Special regenerative brake duty
Rubber bushes
Make cuts in
rubber bush
Insert the connector until
you hear a click sound.
CN8 connector
Wire clamp