360
Inspection item
•
Reinstallation (FR-F720-00105 to 04750, FR-F740-00083 to 03610)
1)After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of "AIR FLOW" faces up.
2)Reconnect the fan connectors.
3)Reinstall the fan cover.
<Fan side face>
AIR FLOW
FR-F720-00340 to 00630
FR-F740-00170 to 00380
FR-F720-00105 to 00250
FR-F740-00083, 00126
FR-F720-01250
FR-F720-00770, 00930
FR-F740-00470, 00620
FR-F720-01540 to 04750
FR-F740-00770 to 03610
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-00105 to 00250
FR-F740-00083, 00126
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-00340 to 01250
FR-F740-00170 to 00620
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
FR-F720-01540 to 04750
FR-F740-00770 to 03610
CAUTION
•
Installing the fan in the opposite of air flow direction can cause the inverter life to be shorter.
•
When installing the fan, use care to prevent wires from being caught between the inverter and fan.
•
Switch the power OFF before replacing fans. Since the inverter circuits are charged with voltage even after power
OFF, replace fans only when the inverter cover is on the inverter to prevent an electric shock accident.