396
511
Parameter 6 for user
0B
8B
5
512
Parameter 7 for user
0C
8C
5
513
Parameter 8 for user
0D
8D
5
514
Parameter 9 for user
0E
8E
5
515
Parameter 10 for user
0F
8F
5
522
Output stop frequency
16
96
5
539
Modbus-RTU communication check time
interval
27
A7
5
542
Communication station number (CC-
Link)
2A
AA
5
543
Baud rate selection (CC-Link)
2B
AB
5
544
CC-Link extended setting
2C
AC
5
549
Protocol selection
31
B1
5
550
NET mode operation command source
selection
32
B2
5
551
PU mode operation command source
selection
33
B3
5
553
PID deviation limit
35
B5
5
554
PID signal operation selection
36
B6
5
555
Current average time
37
B7
5
556
Data output mask time
38
B8
5
557
Current average value monitor signal
output reference current
39
B9
5
563
Energization time carrying-over times
3F
BF
5
×
×
×
564
Operating time carrying-over times
40
C0
5
×
×
×
570
Multiple rating setting
46
C6
5
×
×
571
Holding time at a start
47
C7
5
573
4mA input check selection
49
C9
5
575
Output interruption detection time
4B
CB
5
576
Output interruption detection level
4C
CC
5
577
Output interruption cancel level
4D
CD
5
578
Auxiliary motor operation selection
4E
CE
5
579
Motor connection function selection
4F
CF
5
580
MC switching interlock time
50
D0
5
581
Start waiting time
51
D1
5
582
Auxiliary motor connection-time
deceleration time
52
D2
5
583
Auxiliary motor disconnection-time
acceleration time
53
D3
5
584
Auxiliary motor 1 starting frequency
54
D4
5
585
Auxiliary motor 2 starting frequency
55
D5
5
586
Auxiliary motor 3 starting frequency
56
D6
5
587
Auxiliary motor 1 stopping frequency
57
D7
5
588
Auxiliary motor 2 stopping frequency
58
D8
5
589
Auxiliary motor 3 stopping frequency
59
D9
5
590
Auxiliary motor start detection time
5A
DA
5
591
Auxiliary motor stop detection time
5B
DB
5
611
Acceleration time at a restart
0B
8B
6
653
Speed smoothing control
35
B5
6
654
Speed smoothing cutoff frequency
36
B6
6
665
Regeneration avoidance frequency gain
41
C1
6
726
Auto Baudrate/Max Master
1A
9A
7
727
Max Info Frames
1B
9B
7
728
Device instance number (Upper 3 digit)
1C
9C
7
729
Device instance number (Lower 4 digit)
1D
9D
7
753
Second PID action selection
35
B5
7
Parameter
Name
Instruction Code
*1
Parameter
Copy
*2
Parameter
Clear
*2
All Parameter
Clear
*2
Read
Write
Extended
Summary of Contents for 700 Series
Page 11: ...MEMO ...
Page 23: ...12 MEMO ...
Page 341: ...330 MEMO ...
Page 365: ...354 MEMO ...
Page 379: ...368 MEMO ...
Page 397: ...386 MEMO ...
Page 414: ...403 MEMO ...