4-31
Setting Routine operations
4
Routi
n
e Ma
int
ena
nc
e
Setting Pump tube washing interval in Standby mode
Perform the pump tube washing periodically to prevent ink from clogging due to the coagulation of ink,
which occurs within the tube.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1)
Press the
key in the local mode.
(2)
Select [MAINTENANCE] by pressing the
keys then press the
key.
(3)
Select [ROUTINE SETUP] by pressing the
keys.
(4)
Press the
key.
2
Select [PUMP TUBE WASH] by pressing the
keys.
3
Press the
key.
4
Set the tube washing interval by pressing
the
keys.
•
Set value
:
OFF, 1 - 168 hours
5
Press the
key.
6
Press the
key several times to end.
• This function is operable only under the condition that the machine is left in the following
displays.
• When the cleaning solution has not been filled in the
machine, the right display is displayed at the step 5. Fill the
cleaning solution (
P.4-8) then redo the operations from
the step 1.
< LOCA L . 1 >
[ # 0 1 ]
* REMOT E . 1 *
[ # 0 1 ]
0 . 0 0m
LOCAL mode
REMOTE mode
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
ROUT I NE SE TUP
WASH I NT ERVA L
=
1
h
ROUT I NE SE TUP
WASH I NT ERVA L
=
4
h
ROUT I NE SE TUP
PUMP TUBE WASH < e n t >
* * Wa s h i n g L i q u i d * *
Summary of Contents for TS3-1600
Page 1: ...MIMAKI ENGINEERING CO LTD URL http www mimaki co jp D201937 15...
Page 7: ...vi...
Page 99: ...3 35 Machine settings 3 Convenient use Examples of Output...
Page 101: ...3 37 Machine settings 3 Convenient use 7 Press the key 8 Press the key several times to end...
Page 118: ...3 54...
Page 151: ...Setting Routine operations 4 33 4 Routine Maintenance 8 Press the key several times to end...
Page 164: ...4 46...
Page 189: ...6 13 Function Flowchart 6 Appendix To P 6 14 To P 6 20 To P 6 26 To P 6 27 To P 6 28...
Page 193: ...6 17 Function Flowchart 6 Appendix OFF LEVEL 1 3 1 Wh i t e L a y P r t SE L OF F...
Page 205: ...D201937 15 17022012...
Page 206: ...NH FW 5 3 Printed in Japan MIMAKI ENGINEERING CO LTD 2012...