![Micno KE600 Series Manual Download Page 71](http://html1.mh-extra.com/html/micno/ke600-series/ke600-series_manual_1784752071.webp)
KE600 Inverter Function Parameter List
68
Function
code
Name
Detailed instruction
Factory
default
Modify
A2-46
Vector control over
excitation gain
0 ~ 200
64
○
A2-47
Torque upper limit source
selection in speed control
mode
0: Set by A2-48
1: AI1
2: AI2
3: Keypad potentiometer
4: High speed pulse HDI
5: Communication
6: Min (AI1, AI2)
7: Max (AI1, AI2)
Full scale of 1-7 selection corresponds
to A2-48
0
○
A2-48
Torque upper limit
digital setting
0.0% ~ 200.0%
150.0%
○
A2-51
Proportional gain of
excitation regulation
0~6000
2000
○
A2-52
Integral gain of excitation
regulation
0~6000
1300
○
A2-53
Proportional gain of
torque regulation
0~6000
2000
○
A2-54
Integral gain of torque
regulation
0~6000
1300
○
A2-61
Motor 2 control mode
0: V/f
1: Sensorless vector control
0
◎
5.2 Monitoring Parameter Table
Function code
Name
Minimum unit
U0:Group Basic Monitoring Parameter
U0-00
Running frequency (Hz)
0.01Hz
U0-01
Setting frequency (Hz)
0.01Hz
U0-02
DC bus voltage (V)
0.1V
U0-03
Output voltage (V)
1V
U0-04
Output current (A)
0.01A
U0-05
Output power (kW)
0.1kW
U0-06
Output torque (%)
0.1%
U0-07
DI input status
1
U0-08
DO output status
1
U0-09
AI1 voltage (V)
0.01V