![Micno KE600 Series Manual Download Page 35](http://html1.mh-extra.com/html/micno/ke600-series/ke600-series_manual_1784752035.webp)
KE600 Inverter Mechanical and Electric Installation
32
Digital
Input
D1
Digital input 1
1. Optical coupling isolation, compatible with dual polarity
input
2. Input impedance: 4.7kΩ
3. Voltage range for level input: 9V
~
30V
D2
Digital input 2
D3
Digital input 3
D4
Digital input 4
D5
Digital input 5
D6
Digital input 6
HDI~CME/
D7~COM
High-speed pulse
input terminal
In addition to the characteristics of D1 to D6, it can also be
used as the high speed pulse input channel.
Maximum input frequency is 100kHz
Caution: The CME is internally insulated with the COM, but
they have been short circuited externally (HDI is driven by
+24V by default prior to delivery). When HDI needs to be
driven by the external power, the short circuited between
CME and COM must be disconnected.
Analog
Output
AO1~GND
Analog output 1
The voltage or current output is determined by J3 jumper on
the control board.
Output voltage range: 0V ~ 10V. Output current range: 0mA
~ 20mA.
AO2~GND
Analog output 2
The voltage or current output is determined by J4 jumper on
the control board.
Output voltage range: 0V ~ 10V. Output current range: 0mA
~ 20mA.
Digital
Output
HDO~CME
High speed pulse
output / open
collector output
It can be used as high speed pulse output or open collector
output which is determined by function code P5-00.
High speed pulse output: maximum frequency is 100kHz
Open collector output :Optical coupling isolation, dual
polarity
Output voltage range: 0V~24V
Output current range: 0mA~50mA
Note: The CME is internally insulated with the COM, but
they have been short circuited externally (HDO is driven by
+24V by default prior to delivery). When HDO needs to be
driven by the external power, the CME and COM must be
disconnected.
Relay
Output
1
T1B-T1C
Normally closed
terminal
Driving capacity:
AC 250V, 3A, COS
ø
=0.4
DC 30V, 1A
T1A-T1C
Normally open
terminal