KE600 Inverter MODBUS Communication Protocol
185
When the function code set to be 0.0 s, the communication timeout parameter is invalid.
When the function code set to be valid value, if the interval time between the communication and the next
communication is beyond the communication timeout, the system will report communication failure error
(Err16). At normal circumstances, it is set to be invalid. If in the continuous communication system, set the
parameter, you can monitor the communication status.
Pd-05
Communication Protocol selection
Factory Setting
1
Setting range
0: Nonstandard Modbus protocol
1: Standard Modbus protocol
PD-05=1: Select standard MODBUS protocol
PD-05=0: When reading the command, the sl
ave return is one byte than the standard MODBUS protocol’s,
for details refer to communications Data Structure of this protocol.
Pd-06
Communication Read Current
Resolution
Factory Setting
0
Setting range
0: 0.01A
1: 0.1A
It is used to confirm the output current unit when communication reads output current.