![Micno KE600 Series Manual Download Page 105](http://html1.mh-extra.com/html/micno/ke600-series/ke600-series_manual_1784752105.webp)
KE600 Inverter Parameter Description
102
Setting
value
Function
Description
PB-05, it outputs ON signal.
11
PLC circulation
completion
When the simple PLC has been running for one cycle, it outputs
a pulse signal with width of 250ms.
12
Accumulated running
time arrival
When the accumulated running time of the inverter exceeds the
setting time P8-17, it outputs ON signal.
13
Frequency limiting
When the setting frequency exceeds the frequency upper limit
or frequency lower limit, and the output frequency of the
inverter reaches the frequency upper limit or frequency lower
limit, it outputs ON signal.
14
Torque limiting
In speed control mode, when the output torque reaches torque
limit, the inverter is in stall protection status and outputs ON
signal.
15
Ready for running
When the main circuit and control circuit power supply are
connected, the inverter protection function is invalid, and the
inverter is in running status, it outputs ON signal.
16
AI1>AI2
When analog input AI1 is bigger than AI2, the inverter outputs
ON signal.
17
Frequency upper limit
arrival
When the running frequency reaches frequency upper limit, it
outputs ON signal.
18
Frequency lower limit
arrival (no output when
stop)
When the running frequency reaches frequency lower limit, it
outputs ON signal. The signal is OFF when stop.
19
Under voltage status
output
During under voltage, the inverter outputs ON signal.
20
Communication setting
Refer to the communication protocol
21
Reserved
Reserved
22
Reserved
Reserved
23
Zero-speed running 2
(output when stop)
When the output frequency is 0Hz, the inverter outputs ON
signal. The signal is still ON when stop.
24
Accumulated power-on
time arrival
The accumulated power-on time (P7-13) exceeds the time set
by P8-16, the inverter outputs ON signal.
25
FDT2 output
Please refer to P8-28, P8-29 description.
26
Frequency 1 arrival
output
Please refer to P8-30, P8-31 description.
27
Frequency 2 arrival
output
Please refer to P8-32, P8-33 description.
28
Current 1 arrival output
Please refer to P8-38, P8-39 description.
29
Current 2 arrival output
Please refer to P8-40, P8-41 description.
30
Timing arrival output
When timing function selection (P8-42) is valid, after the
running time arrives the set timing, outputs ON signal.
31
AI1 input over limit
When analog input AI1 is bigger than P8-46 (AI1 input
protection upper limit) or lower than P8-45 (AI1 input protection
lower limit), outputs ON signal.
32
Off load
When inverter is in the off-load state, it outputs ON signal.
33
Reverse running
When reverse running, the inverter outputs ON signal.
34
Zero current status
Please refer to description of P8-34, P8-35.
35
Module temperature
arrival
The temperature of converter module radiator (P7-07) reaches
the set value of module temperature arrival (P8-47), the inverter
outputs ON signal.