![Micno KE600 Series Manual Download Page 69](http://html1.mh-extra.com/html/micno/ke600-series/ke600-series_manual_1784752069.webp)
KE600 Inverter Function Parameter List
66
Function
code
Name
Detailed instruction
Factory
default
Modify
A0-00
Speed/torque control
mode selection
0: Speed control
1: Torque control
0
◎
A0-01
Torque setting source
selection in torque control
mode
0: Keypad (A0-03)
1: AI1
2: AI2
3: Keypad potentiometer
4: High speed pulse HDI
5: Communication
6: Min (AI1,AI2)
7: Max (AI1,AI2)
0
◎
A0-03
Torque setting through
keypad in torque control
mode
-200.0% ~ 200.0%
150.0%
○
A0-04
Torque filter time
0.00s ~ 10.00s
0.00s
○
A0-05
Forward maximum
frequency in torque
control mode
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
A0-06
Reverse maximum
frequency in torque
control mode
0.00Hz ~ P0-10 (maximum frequency)
50.00Hz
○
A0-07
Acc time in torque control
mode
0.00s ~ 36000s
0.00s
○
A0-08
Dec time in torque control
mode
0.00s ~ 36000s
0.00s
○
A2 Group: Motor 2 Parameters
A2-00
Motor type
0: Common asynchronous motor
1: Variable frequency asynchronous
motor
0
◎
A2-01
Rated power
0.1kW ~ 1000.0kW
Model
depend
◎
A2-02
Rated voltage
1V ~ 2000V
Model
depend
◎
A2-03
Rated current
0.01A ~ 655.35A
( Inverter power≤55kW )
0.1A ~ 6553.5A
( Inverter power
>
55kW )
Model
depend
◎
A2-04
Rated frequency
0.00Hz ~ P0-10 (max. frequency)
Model
depend
◎
A2-05
Rated speed
1RPM ~ 36000RPM
Model
depend
◎
A2-06
Stator resistance
0.001
Ω ~ 65.535Ω
(
Inverter power≤55kW)
Motor
paramet
◎