45 / 72
HBC-series V7 LV+MV
P16:
Acceleration, increasing of the power (rpm), time from 0% power to 100%
(values in milliseconds)
Sets the time (speed) stopped the engine acceleration from 0 to 100% power. Apply in proportion anytime between any levels.
P18:
Deceleration, decreasing of the power (rpm), time from 100% power to 0
(values in milliseconds)
Time necessary for decrease rpm from full value to zero (from 100% to 0) when move throttle (joystick) from full throttle position to STOP. This is
important mainly when going from full throttle forward to full throttle backwards (and vice-versa). That is, motor decelerates to zero with the set
speed and then accelerates to the other direction with the speed set in parameter "
P16
" - acceleration.
If
Freewheel
parameter („
P21
“) is set, deceleration is not so strong.
P17:
Acceleration from STOP position, RPM rise time from 0% to 100% - only for the "constant speed" mode
(in milliseconds)
The function can be activated only for constant speed mode. This function is useful if you need to accelerate greater inertia of a complete stop
slower, but if the engine is running, it can accelerate / decelerate faster.
Set the time (speed) acceleration of the stopped motor from 0 to 100% power. This acceleration is valid only for start from STOP position to
achieve value of the control signal. When reaching the stabilization RPM, acceleration ramp switches to value defined in parameter P16, which
remains to stop the engine (up to transition of the control signal to STOP position)
– then reactivates P17 value.
If you do not use this function, set the value equal to or less than P16.
100%
0%
0,5 sec.
1,0 sec.
motor PWM, unloaded motor rpm
Control signal
Joystick (throttle) moving
Acceleration ramp
P16=0,5 sec
.
Deceleration ramp
P18=1,0 sec
.
Acceleration / deceleration
(without freewheel):
Changing the control signal is slower than corresponds to the acceleration
and deceleration - output (motor) PWM follows the control signal
+100%
0%
(STOP)
0,5 sec.
1,0 sec.
60%
0,4 sec.
0,2 sec.
∆ = 40%
sec.
motor PWM, unloaded motor rpm
Control signal
Joystick (throttle) moving
Acceleration ramp
P16=0,5 sec
.
Deceleration ramp
P18=1,0 sec
.
Acceleration / deceleration
(without freewheel), control type: boat bidirectional:
–100%
0,5 sec.
Acceleration ramp
P16=0,5 sec
.
Motor start to rotate to other side
0,5 sec.
0,3 sec.
∆ = 40%
sec.
100%
0%
Motor rpm
Acceleration
ramp
P16=0,5 sec
.
Deceleration ramp
P18=1,0 sec
.
Control signal
Joystick (throttle)
moving
Acceleration ramp
P17=1,5 sec
.
Acceleration ramp
P17=1,5 sec
.
(stopped motor starts)
Moment of Rpm stabilized
Acceleration ramp
P16=0,5 sec
.
Rpm stabilized
STOP
STOP
const. rpm
const. rpm
const. rpm