37 / 72
HBC-series V7 LV+MV
Programmable parameters
Parameters setting by user, including default values for all memory banks (type of driving):
Table continues on the next page
parameter
range
step
Bank #1
Bank #2
Bank #3
Bank #4
Default settings
Default settings
Default settings
Default settings
P1
Memory bank
1
4
H
Bank #1
Bank #2
Bank #3
Bank #4
P3
Basic type of behavior
H
Car
Boat
Aircraft
Aircraft
P2
Direction mode
H
Bidirectional
Bidirectional
One way
One way
P69
Control type
H
PWM
PWM
PWM
Constant rpm
P5
Controller start behavior
safe
safe
safe
safe
P4
Control signal
H
By HW configuration By HW configuration
By HW configuration
By HW configuration
P33
Control signal limits setting lock
H
Allowed
Allowed
Allowed
Allowed
P90
Signal limits monitoring
H
Yes
Yes
Yes
Yes
Control signal limits-main channel
P6
Full throttle Forward
1,6 ms
0,15 V
2,3 ms
3,15 V
1µs
1mV
2,0 ms / 3,15 V
2,0 ms / 3,15 V
2,0 ms / 3,15 V
2,0 ms / 3,15 V
P7
STOP / Neutral
1,0 ms
0,15 V
1,7 ms
3,15 V
1µs
1mV
1,5 ms / 1,65 V
1,5 ms / 1,65 V
1,5 ms / 1,65 V
1,5 ms / 1,65 V
P8
Full throttle Backward / (Full Brake)
0,7 ms
0,15 V
1,4 ms
3,15 V
1µs
1mV
1,0 ms / 0,15 V
1,0 ms / 0,15 V
1,0 ms / 0,15 V
1,0 ms / 0,15 V
Control signal limits
– aux. channel
P9
Full throttle Forward
/
Full Brake
(for divided control BRAKE
/
THROTTLE)
1,6 ms
0,15 V
2,3 ms
3,15 V
1µs
1mV
2,0 ms / 3,15 V
2,0 ms / 3,15 V
2,0 ms / 3,15 V
2,0 ms / 3,15 V
P10
STOP / Neutral
1,0 ms
0,15 V
1,7 ms
3,15 V
1µs
1mV
1,5 ms / 1,65 V
1,5 ms / 1,65 V
1,5 ms / 1,65 V
1,5 ms / 1,65 V
P11
Full throttle Backward / (Full Brake)
0,7 ms
0,15 V
1,4 ms
3,15 V
1µs
1mV
1,0 ms / 0,15 V
1,0 ms / 0,15 V
1,0 ms / 0,15 V
1,0 ms / 0,15 V
P12
Neutral throttle range
(STOP area)
5%
25%
1%
15%
15%
5%
5%
P13
Throttle terminal points toleration
1%
25%
1%
5%
5%
5%
5%
P58
Emergency disconnecting input
H
off
off
off
off
P41
Enabling input (Gate)
H
off
off
off
off
P92
Safety switch (KEY)
H
No
No
No
No
P53
„Reversing or Brake“ Point
0
100
1%
10
10
--
--
P42
Controller feeding
H
Automat 78%
Automat 78%
Automat 78%
Automat 78%
P43
Number of cells
1
250
1
1
1
1
1
P78
Battery capacity
0,1
250
0,1Ah
0,1
0,1
0,1
0,1
P44
Switch-off voltage / cell
(for P42=UNI)
0,1V
63V
0,1V
0,1
0,1
0,1
0,1
P45
"empty battery" behavior
H
Power reduction
Power reduction
Power reduction
Power reduction
P77
"empty battery" in advance warning
–
alarm when
the voltage
drops below
:
0,1V
63V
0,1V
0,1
0,1
0,1
0,1
P87
"empty battery" in advance warning
–
alarm when
battery charge
drops below
:
0%
50%
1%
20%
20%
20%
20%
P72
Max. power supply voltage
1V
63V
1V
63
63
63
63
P19
Max. current
(% of max. short time current)
10%
100%
1%
100%
100%
100%
100%
P20
Power (PWM) limiting backward
10%
100%
1%
100%
100%
--
--
P46
Motor type
(+Automatic sensor settings)
H
Sensorless
Sensorless
Sensorless
Sensorless
P47
Number of motor poles
2
60
2
2
2
2
2
P51
Motor PWM frequency
8 kHz
32 kHz
H
8 kHz
8 kHz
8 kHz
8 kHz
P52
Motor timing
0°
30
1°
0°
0°
0°
0°
P83
Minimal starting power
0
100
1%
0
0
0
0
P54
Motor basic spin direction
H
correct
correct
correct
correct
P48
Mechanical gear of the system X:1
1
600.00
0.01
1.00
1.00
1.00
1.00
P49
Wheel diameter
1
1000
1mm
P50
System Rpm Limit
(on output shaft)
10
250.000
10
250.000
250.000
250.000
250.000
P86
Motor Rpm Limit
10
250.000
10
250.000
250.000
250.000
250.000