63 / 72
HBC-series V7 LV+MV
Update SW inside the controller (firmware)
When you want make update firmware in you controller to newest available version, you need
USBCOM 4
module (or in case of feeding from
power supply
USBCOM 4i
module
– isolated version) and
CC_11
cable (the same as for standard programming of parameters).
Controller must be connected to internet.
Starting sequence for firmware updating follows:
0.
Connect USBCOM 4(i) module to PC and Start program
Controller 2
first.
Connect controller, but no turn-on yet.
1.
Choice button “SYSTEM”
2.
Choice “Firmware update”
3.
Windows “Firmware update” open
4.
Turn-on your speed controller by its switch or applying main voltage.
Your device version as well as available firmware version is displayed.
(
If you already had the controller is switched on,
now it must be switched off and on again
)
5.
Push “Update” button release.
6.
Confirm firmware updating
CC_11
0
2
1
3
5
6
Yes
No
4