Removing the static flushing device—SPS 200, SPS 300 and SPS 400
pumps with cast iron power frame
Note
: The flushing device (if fitted) must be emptied and removed before dismantling the pump.
•
Use a 19mm spanner to loosen the retaining nut holding the bent outlet in position (arrowed)
enough to allow the bent outlet to be lowered into a horizontal position.
•
Hold a vessel under the bent outlet. Drain until no more liquid runs out of the power frame.
•
Remove the retaining nut holding the sight glass and its connection pieces in position and remove
the sight glass and its connection pieces. Remove the bent outlet in the same way.
Fitting a flush ring without flush connections—SPS 200, SPS 250, SPS 300,
SPS 400 and SPS 500 pumps with stainless steel power frame
The SPS 300 is shown here. Flushing options for the SPS 200, SPS 250, SPS 400 and the SPS 500 are
similar.
86
m-SPS-en-08
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...