Removing the static flushing device—SPS 100 pumps
Note
: The flushing device (if fitted) must be emptied and removed before dismantling the pump.
•
To remove the static flushing device, pour the flushing fluid from the sight glass, and reverse the
sequence of operations described above.
23.2 SPS 200, SPS 300, SPS 400 and SPS 500
Fitting the static flushing device—SPS 200, SPS 300 and SPS 400 pumps
with cast iron power frame
The static flushing device for the SPS 300 is shown here. The static flushing devices for the SPS 200 and
the SPS 400 are similar.
•
Use a 6mm Allen key to remove the two nipples (arrowed) (if fitted) from the pump’s power frame.
•
Fit the sight glass connection piece in place of the top nipple. Use a 19mm spanner to tighten it. Fit
the sight glass and tighten the retaining nut to hold it in position.
•
Fit the bent outlet in place of the bottom nipple in the same way.
•
Fill the system with flushing fluid to the level of the top bend of the bent outlet.
m-SPS-en-08
85
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...