Picture 1
Picture 3
Picture 2
•
If this dimension is not correct, use a wrench to loosen and remove the screws securing the bearing
housing to the power frame (arrowed; the number of screws varies with pump model). (Picture 1).
•
For SPS 200: 13mm wrench
•
For SPS 250: 13mm wrench
•
For SPS 300: 16mm wrench
•
For SPS 400: 18mm wrench
•
For SPS 500: 18mm wrench
•
Remove the bearing housing and the pump shaft, being careful not to damage lip seals (arrowed).
(Picture 2).
•
Remove the shim ring (arrowed) and install a new one between the power frame and the bearing
housing. (Picture 3) Reassamble, tightening the bearing housing retaining screws as follows:
•
For SPS 200 M8: 16 Nm
•
For SPS 250 M8: 16 Nm
•
For SPS 300 M10: 33 Nm
•
For SPS 400 M12: 56 Nm
•
For SPS 500 M12: 56 Nm
•
Measure dimension X again.
•
If this dimension is not correct, disassemble and peel layers from the shim ring equal in total
thickness to the difference between the re-measured distance and the correct distance, so that the
correct dimension X is achieved. One layer is 0.05mm thick.
•
Reassemble.
m-SPS-en-08
37
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...