![masosine SPS 100 User Manual Download Page 54](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328054.webp)
Dismantling the pump housing— SPS 200 pumps with a cast iron power frame and a single
mechanical seal
Note
: See "Dismantling the pump housing—SPS 200 pumps with a stainless steel power frame and a
single mechanical seal" on page 58 for dismantling the pump housing of a pump with a cast iron power
frame.
•
Use a 13mm spanner to loosen and remove the two screws (right-hand thread) and washers which
secure the pump housing to the power frame.
•
If necessary, gently tap the pump housing with a soft hammer to free it. Withdraw the pump
housing carefully.
The pump housing is heavy.
54
m-SPS-en-08
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...