![masosine SPS 100 User Manual Download Page 44](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328044.webp)
•
Position the static face in the mechanical seal, with the static face’s O-ring facing the mechanical
seal. The static face has two recesses (arrowed) which must be correctly aligned with lugs
(arrowed) either side of its seat
•
Use a finger to retain the static face in position on the mechanical seal and push them on to the
pump shaft and all the way home into the pump housing.
Note
: The mechanical seal has a lug on
its inner surface which must be aligned with the shaft splines.
SPS 100 pumps with a triple lip seal: fitting the distance piece
•
Check that the distance piece O-ring is in position.
•
Push the distance piece into position, flanged end first.
Pumps with a triple lip seal: fitting the back bushing
•
Push the back bushing into position, thick end (arrowed) towards the front. (The two bushings are
identical.)