21
Adjusting the shaft
21.1 SPS 200, SPS 250, SPS 300, SPS 400 and SPS 500 pumps
It is important that dimension X is correct to achieve efficient pumping.
Note
: Dimension X in all pumps may be measured as below. However, the structure of the SPS 100 pump
casing is different from other models (and not as shown here) and SPS 100 dimension X is adjusted
differently. SPS 100 pumps must be returned to MasoSine for dimension X adjustment.
21.2 Adjusting dimension X in models with cast power frame
SPS 200, SPS 300 and SPS 400 pumps
Dimension X
Shim ring
Power frame
Bearing housing
Lip seals
Shaft
Bearing housing
retaining screw
Vernier
Shaft
sleeve
Dimension X
SPS 100
SPS 200
SPS 300
SPS 400
10.0mm +0.05
17.5mm +0.1
23.0mm +0.1
15.0mm +0.1
SPS 200, SPS 300 and SPS 400: adjusting dimension X
Note
: SPS 100 pumps must be returned to MasoSine for dimension X adjustment.
•
Remove the front cover, the front support, the front liner, the rotor, the gate and the gate guide.
See "Disassembly and assembly" on page 38.
•
Measure dimension X.
•
Check this dimension against the table above.
34
m-SPS-en-08
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...