![masosine SPS 100 User Manual Download Page 31](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328031.webp)
19
Changing the oil
19.1 SPS 100
Every day before using your pump, check that there is enough grease in the storage chamber. Remove
the vent at
A
and insert grease through the nipple at
B
until grease starts to come out at
A
. Refit the
vent.
Standard first filling, for -10 to 60°C (14 to 140°F): MOLYDUVAL Soraja C532, DIN 51502.
Grease grades for Ex zones:
•
At temperature class T4 (60°C (140°F) or less: MOLYDUVAL Soraja C532, DIN 51502.
•
At temperature class T3 (61 to 120°C (142 to 248°F) or less: MOLYDUVAL Pegasus KD 460.
C
A
B
19.2 SPS 200, SPS 250, SPS 300, SPS 400, SPS 500
Every day before using your pump, check the oil viewing glass at B (see 27 in the parts list,"Parts lists"
on page 91) in the bearing housing (see 11 in the parts list, "Pumps" on page 92) for damage and to
confirm that enough oil is in the power frame. The oil should reach the middle of the glass.
•
Check that the drain plug
C
is in place and fully tightened.
•
Open port
A
and fill the power frame with suitable oil (see Note, below) until it is nearly full.
•
Close port
A
.
•
Check the oil level in viewing glass at
B
. Do not allow the level to fall below the viewing glass
centre line.
Note
: If the pump is intended to be used in an area where ATEX regulations apply, the oil viewing glass is
replaced by a screwed plug.
Note
: When a new pump is supplied, it is filled as standard with Klüberoil 4 UH 1-220 N lubrication oil for
the food and pharmaceutical industries, which is suitable for process temperatures between –30C (-22F)
and 120C (248F).
If the pump is intended to be used in an area where ATEX regulations apply, only
this oil must be used.
Filling volumes
SPS 200
SPS 250
SPS 300
SPS 400
SPS 500
Cast iron power frame
Approx 0.10
litre
N/A
Approx 0.18
litre
Approx 0.38
litre
N/A
Stainless steel power
frame
Approx 0.10
litre
Approx 0.10
litre
Approx 0.18
litre
Approx 0.35
litre
Approx 0.45
litre
Dispose of used oil according to local regulations.
Oil or grease needs to be changed at least once a year.
m-SPS-en-08
31
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...