Fitting the static face and the seal—SPS 200 pumps with a single mechanical seal
The mechanical seal
The static face
•
Check that the seal housing O- ring is properly positioned in its groove in the pump housing
(arrowed in bottom left picture), and that the two O-rings either side of the mechanical seal are
properly positioned (arrowed above).
•
Position the static face in the mechanical seal. The static face has two recesses (arrowed) which
must be correctly aligned with lugs (arrowed) either side of its seat.
•
Push the mechanical seal into the pump housing.
Note
: The mechanical seal is a tight push fit.
m-SPS-en-08
59
Summary of Contents for SPS 100
Page 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Page 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Page 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Page 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Page 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Page 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Page 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Page 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Page 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Page 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...